77777
Disassembly and Assembly Procedures
Disassembly Process of Indoor Unit
Operating Procedures/Photos
Disassemble the Front panel
Disassemble air guide louver
Bend the air guide louver by hands, and then
loose the slipknot on the guide louver to disassemble
the guide louver.
Air guide louver
Filter
Screw Electric box top cover
Front panel
Wire terminal
Open the front panel. Firstly to screw off the screws
that fixed at the guard plate on the receiving window
both sides, disassemble the guard plate, then to
remove the wiring terminal, then along the groove
that fix the front panel to take out the front panel.
Disassembling the filter and wire-pressed clamp
Disassemble the filter, screw off the screw that
fix the wire-pressed clamp can disassemble it.
Summary of Contents for ACP-18CH50GEI
Page 1: ...ACP 18CH50GEI RoHS Service manual ENG ...
Page 2: ......
Page 8: ...Overall and Installing Dimension of Indoor Unit 24K Unit mm Bolt Nut Wrench ...
Page 9: ...5 5 5 5 5 Electrical Diagram ACP 18CH50GEI ...
Page 31: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit ...
Page 33: ...Exploded View of Indoor Unit ...
Page 35: ...Exploded View of Outdoor Unit ...
Page 37: ...Exploded View of Outdoor Unit ...
Page 45: ......
Page 46: ......
Page 47: ......