12. Liquid pipe and drain pipe
INSTALATION INSTRUCTIONS
IF THE OUTDOOR UNIT IS INSTALLED
LOWER THAN THE INDOOR UNIT(picture 1)
1. A drain pipe should be above ground and the end of the pipe
does not dip into water. All pipes must be restrained to the wall
by saddles.
2. Taping of the pipes must be done from bottom to top.
3. All pipes are bound together by tape and restrained to the wall by
saddles
IF THE OUTDOOR UNIT IS INSTALLED
HIGHER THAN THE INDOOR UNIT(picture 2)
1. Taping should done from lower to upper part.
2. All pipes are bound and taped together and trapped the pipes
to prevent water returning to the room. (see picture)
3. Restrain all pipes to the wall with saddles