![Vivax ACP-12CT32AEI/I Service Manual Download Page 8](http://html.mh-extra.com/html/vivax/acp-12ct32aei-i/acp-12ct32aei-i_service-manual_1038060008.webp)
MCAC-UTSM-2008-04
Specifications
Indoor units
11
Fin type (code)
Hydrophilic aluminium
Hydrophilic aluminum
Tube outside dia.and type
mm
Φ
9.5 innergroove tube
Φ
9.5 Innergroove tube
Coil length x height x width
mm
637*558*44
748*660*44
Number of circuits
2
2
Outdoor air flow
m
3
/h
2500/1600
2400/1680
Sound level
(
sound pressure
)
dB(A)
48/44
52/47
Dimension(WxDxH)
mm
761
×
593
×
279
842
×
695
×
324
Packing (WxDxH)
mm
887
×
655
×
355
965
×
770
×
395
Outdoor unit
Net/Gross weight
kg
42/45
62/66
Type
R410A
R410A
Refrigerant
Charged volume
g
1400
1700
Throttle type
Capillary
EXV
Design pressure (Hi/Lo)
MPa
4.2/2.0
4.2/2.0
Liquid side/ Gas side
mm
φ
6.4/12.7
φ
6.4/12.7
Max. refrigerant pipe length
m
10
20
Max.
difference
in
level(Outdoor is up)
m
5
10
Refrigerant piping
Max. difference in level
(Outdoor is down)
m
5
10
Power wiring (Indoor)
mm
2
3 core x 1.5
——
Power wiring (Outdoor)
mm
2
——
3 core
×
2.5
Connection wiring
Signal wiring
mm
2
4-core shielded wire
×
1.5
3-core shielded wire
x0.5
Wireless remote controller (Indoor)
R51D/E
Operation temp (Indoor)
℃
17
~
30
Ambient temp (Outdoor)
-10~43
Cooling -15~43
Heating -15~21
°
文件使用
"pdfFactory Pro"
试用版本创建
www.fineprint.cn
Summary of Contents for ACP-12CT32AEI/I
Page 1: ...ACP 12CT32AEI I ACP 12CT32AEI O RoHS Service manual ENG ...
Page 2: ......
Page 59: ......
Page 60: ......
Page 61: ......