Troubleshooting
MCAC-UTSM-2008-04
42
Outdoor Units
4. Running and Timer lamp flash at 5Hz
5. Running lamp Timer lamp and Defrosting lamp flash at 5Hz:
Running and Timer lamp flash at 5Hz
EEPROM malfunction
Judge 1: Check whether the EEPROM is inserted well
Yes
No
Insert the EEPROM well
Replace outdoor main board
Running lamp Timer lamp and Defrosting lamp flash at 5Hz
Check whether the wiring of the Condenser temperature sensor
is break off
Replace outdoor main board
Judge 1: Condenser temperature sensor is malfunction
Connect the wiring well
Yes
No
Check whether the resistance of Condenser temperature sensor
is wrong refer to the Annex 1
Yes
Replace Condenser
temperature sensor
No