MCAC-UTSM-2008-04
Troubleshooting
Outdoor Units
51
4. E4 malfunction
5. E5 malfunction
LED indicates E4
Check whether the wiring of the outdoor ambient temperature
sensor (T4) is break off
Replace outdoor main board
Judge 1: Outdoor ambient temp. sensor (T4) is malfunction
Connect the wiring well
Yes
No
Check whether the resistance of outdoor ambient temperature
sensor (T4) is wrong refer to the Annex 1
Yes
Replace outdoor ambient
temperature sensor (T4)
No
LED indicates E5
Outdoor unit voltage protection
Check the voltage of outdoor unit power supply, whether the
voltage between L1 and N is about 198-254V
No
Replace the power board, then check whether the system can
run normally
Check the power supply
Yes
Replace outdoor
main board
Yes
Trouble is solved
No