![Vivax ACP-12CT32AEI/I Service Manual Download Page 46](http://html.mh-extra.com/html/vivax/acp-12ct32aei-i/acp-12ct32aei-i_service-manual_1038060046.webp)
MCAC-UTSM-2008-04
Troubleshooting
Outdoor Units
49
2. E2 malfunction
LED indicates E2
Communication malfunction between indoor/outdoor units
Judge 3: Check whether the signal wiring between the
indoor and outdoor units is wrong polarity?
Connect the signal wiring correctly
Yes
No
Judge 4: Check whether the signal wiring between the
indoor and outdoor units is broken?
Yes
Replace the broken wiring
No
Judge 2: Check whether the signal wiring is shield cable
or whether the shield cable is earthing
Yes
Adopt the shield cable/ shield cable earthing
No
Indoor or outdoor main board is broken, replace the
main board until the malfunction is disappear
Judge 1: Check whether the indoor unit power is on
Turn on the indoor unit power
No
Yes
文件使用
"pdfFactory Pro"
试用版本创建
www.fineprint.cn
Summary of Contents for ACP-12CT32AEI/I
Page 1: ...ACP 12CT32AEI I ACP 12CT32AEI O RoHS Service manual ENG ...
Page 2: ......
Page 59: ......
Page 60: ......
Page 61: ......