Wiring
2
Open the front grille;
Remove the screw from electrical box cover, pull the
electrical box cover away from the unit and set aside.
Remove the screw from fastener, pull the fastener
away from the unit and set aside.
Connect the cable.
Replace the fastener and electrical box cover.
Indoor unit terminal
Screw
Connecting cable
Diagram
INSTALLATION
The drain hose must be arranged beneath the copper pipe.
The drain hose must not be hunched or twisted.
While wrapping up the drain hose, do not pull it.
The drain hose through the room must be wrapped up by the
thermal insulation materials.
The copper pipe and the drain hose must be wrapped up by felt
strip. Adiabatic pad should be used at where the pipe contacts
the wall.
NOTE:
1
2
3
ROUTE OF PIPE
If pipe comes out of the right side of the indoor unit, cut part
1
of the unit;
If pipe comes out of the lower-right side of the indoor unit, cut
part
2
of the unit;
If pipe comes out of the left side of the indoor unit, cut part
3
of the unit.
Installation of the drain hose
3
Drain hose
gas pipe
Liquid pipe
felt
Adiabatic
underlay
drain hose
If pipe comes out of the left side of the indoor unit, the drain hose
must be refitted, otherwise water leakage may occur.
Refit methods: Interchange the position of drain hose and drain
rubber plug.
Clearance is not allowed after refit, it would lead to water leakage.
Drain rubber
plug
REFIT OF DRAIN HOSE
5
NOTE:
The appliance shall be installed in accordance with national wiring regulations.
The appliance must not be installed in the laundry.
The appliance must be installed 2.3m above the floor.
The appliance must be positioned so that the plug is accessible.
For some models whose cooling capacity are above 4600W (17000BTU/h),
an all-pole disconnection device which has at least 3mm separation distance in
all pole and a residual current device(RCD)with the rating of above 10mA shall
be incorporated in the fixed wiring according to the national rule.
Summary of Contents for ACP-09CH25ZNM
Page 1: ...ACP 09CH25ZNM ACP 12CH35ZNM RoHS Service manual ENG ...
Page 2: ......
Page 29: ...Outdoor unit Exploded Views and Parts List 27 AUS 07C53R010Lx ACP 09CH25ZNM ...
Page 31: ...Outdoor unit Exploded Views and Parts List 29 AUS 07C53R010Lx ACP 09CH25ZNM ...
Page 33: ...Outdoor unit Exploded Views and Parts List 31 ACP 12CH35ZNM ...
Page 35: ...Outdoor unit Exploded Views and Parts List 33 ACP 12CH35ZNM ...
Page 37: ...Outdoor unit Exploded Views and Parts List 35 AUS 12C53R130Lx ...
Page 39: ...Exploded Views and Parts List Outdoor unit 37 AUS 12H53R130Lx ...
Page 43: ...Wiring Diagrams Indoor unit ACP 12CH35ZNM Outdoor unit 41 ACP 12CH35ZNM IFAN ...
Page 44: ......
Page 45: ......
Page 46: ......