DRY MODE
In this mode, the air conditioner automatically sets the room temperature and this temperature
is incontrollable by remote controller. The initial ST =RT-2
.
Control during dry mode:
a. When RT<15
, dry mode is not available; when RT 15
, the compressor intermittently
runs under the influence of TS and RT.
b. When RT
23
, if RT
ST, the compressor runs intermittently as this:
Run for 8 minutes Stop for 3 minutes
If RT<ST, the compressor runs intermittently as this:
Stop for 4 minutes Run for 1 minute
c. When RT<23
, if RT
ST, the compressor runs intermittently as this:
Run for 2 minutes Stop for 3 minutes
If RT<ST, the compressor runs intermittently as this:
Stop for 4 minutes Run for 1 minute
d. In this mode, the indoor fan keeps running at low speed with the same pace as the compressor,
and this speed can not be controlled by remote controller.
CONTROL SPECIFICATION
AUTO MODE
Mode
Mode
24
26
RT-2
RT-2
Cool
Cool
Dry
RT-2
RT-2
Dry
Heat
24
21
Room
Temperature (RT)
RT
26
25
RT
23
RT
23
26
RT
25
Heat pump type
Cool only type
Initial Setting Temperature
Initial Setting Temperature
In this mode, the air conditioner can automatically adjust the room temperature to decide the most
suitable temperature. At the start of operation, the unit will automatically select the operation mode
according to the room temperature. The following table shows the conditions which are set at start up.
Auto mode entering
a. Once some operation mode is determined, it can not be changed even if the RT has altered.
b. You can change the operation mode by remote controller.
If restart within 2 hours, the unit will resume the same operation mode as before.
If restart after 2 hours, the unit will select the operation mode according to the initial room temperature.
At auto mode the ST can only be set + or - 2
of the RT.
19
Summary of Contents for ACP-09CH25ZNM
Page 1: ...ACP 09CH25ZNM ACP 12CH35ZNM RoHS Service manual ENG ...
Page 2: ......
Page 29: ...Outdoor unit Exploded Views and Parts List 27 AUS 07C53R010Lx ACP 09CH25ZNM ...
Page 31: ...Outdoor unit Exploded Views and Parts List 29 AUS 07C53R010Lx ACP 09CH25ZNM ...
Page 33: ...Outdoor unit Exploded Views and Parts List 31 ACP 12CH35ZNM ...
Page 35: ...Outdoor unit Exploded Views and Parts List 33 ACP 12CH35ZNM ...
Page 37: ...Outdoor unit Exploded Views and Parts List 35 AUS 12C53R130Lx ...
Page 39: ...Exploded Views and Parts List Outdoor unit 37 AUS 12H53R130Lx ...
Page 43: ...Wiring Diagrams Indoor unit ACP 12CH35ZNM Outdoor unit 41 ACP 12CH35ZNM IFAN ...
Page 44: ......
Page 45: ......
Page 46: ......