Operating Procedures / Photos
Press the clasps in by till they loose, then lift up
wards the electric cover.
4. Disassemble the electric cover
5. Disassemble water tray
Electric cover
5. Disassemble the electric box
Screw off the grounding wire of the evaporator,
remove the tube sensor and temp sensor support,
put out the connection lines for the step motor
and the indoor motor. Screw off the screws fixing
the electric box. Remove the electric box.
Grounding wire
Connector
Tube Sensor
Temp Sensor Support
Clasps
Clasp
Water tray
Loosen up the clasp at the front of and the rear of
water tray sub-assy and lift them up, can take out
the water tray sub-assy.
Note: Due to the water tray is connected with the
water drainage pipe, please pay more attention do
not to damage the fin on evaporator.
Summary of Contents for ACP-09CH25GEH
Page 1: ...ACP 09CH25GEH ACP 12CH35GEH ACP 18CH50GEH RoHS Service manual ENG ...
Page 2: ......
Page 13: ...913 378 680 550 342 ACP 18CH50GEH O Bolt Nut Wrench Unit mm ...
Page 14: ...GWHN24DCNK3A1A O 7PKV OO QNV 0WV 9TGPEJ ...
Page 17: ......
Page 54: ...Exploded View of Components and Parts of Indoor unit ᑇ ޚ ...
Page 56: ... 18 24 Exploded View of Components and Parts of Indoor unit ...
Page 58: ... 09 Exploded View of Components and Parts of outdoor unit ...
Page 60: ... 12 Exploded View of Components and Parts of outdoor unit ...
Page 62: ... 18 Exploded View of Components and Parts of outdoor unit ...
Page 64: ... 24 Exploded View of Components and Parts of outdoor unit ...
Page 66: ... 09X2 Exploded View of Components and Parts of outdoor unit ...
Page 68: ... 09 12 Exploded View of Components and Parts of outdoor unit ...
Page 70: ... 12X2 Exploded View of Components and Parts of outdoor unit ...
Page 77: ......
Page 78: ......
Page 79: ......