INSTRUCTIONS FOR USE

4. Set up the patch

4.1.

 Carefully remove 

Side 1

 

from the adhesive.

4.2.

 

Align the metal temperature 

sensor

 on the Fever Scout™ patch 

with the hole in the adhesive.

4.3.

 Attach the Fever Scout™ 

patch to the adhesive. Press 

firmly on the adhesive to 

secure the contact. Carefully 

remove 

Side 2 

from the 

adhesive.

6

Summary of Contents for FEVER SCOUT VV200

Page 1: ...Continuous monitoring thermometer INSTRUCTION FOR USE...

Page 2: ...structions for Use 4 Extended Range Monitoring 10 Cloud Monitoring 11 Normal Body Temperature Ranges 13 Charging Storage Maintenance 14 Troubleshooting 15 Technical Speci cation 16 Certi cation Discla...

Page 3: ...Fever Scout Patch x1 Charger x1 AAA Battery x3 WHAT S INSIDE Disposable Adhesives x8 2 3 1 1 4...

Page 4: ...sensor LED light indicator Charging pins Charging plate Adhesive storage Battery compartment Fever Scout Patch Charger The Fever Scout patch is powered by a rechargeable lithium battery For proper di...

Page 5: ...o not submerge the Fever Scout patch in the water Patch may be removed for bath or shower and re applied after 9 Do not excessively bend or twist the Fever Scout patch 10 In order to hear the noti cat...

Page 6: ...being charged Important You must place the Fever Scout patch in the charger to activate the patch Skip Sign up Sign in Create Account Store and share your temperature data 2 1 Download the app by sear...

Page 7: ...our Bluetooth feature is on 3 2 Place the Fever Scout patch on the phone and select Start pairing 3 3 Once the Fever Scout patch is paired make sure the serial no on the screen matches the one on the...

Page 8: ...Side 1 from the adhesive 4 2 Align the metal temperature sensor on the Fever Scout patch with the hole in the adhesive 4 3 Attach the Fever Scout patch to the adhesive Press rmly on the adhesive to se...

Page 9: ...a is clean and dry Place the Fever Scout patch under the arm so that the metal temperature sensor purple side is closest to the armpit 5 2 Let your arm drop at your side to cover the Fever Scout patch...

Page 10: ...stop close the app and place the Fever Scout patch back on the charger Less than or equal to 98 6 F 37 C Between 98 6 F 37 C and the set alert Greater than or equal to the set alert Note If Bluetooth...

Page 11: ...5 F 05 04PM Apr 05 16 Add notes 96 9 F 03 17PM Apr 05 16 Add notes 97 2 F back Note History NOTE VIEW ADD NOTES Katie Add a Note HOME SCREEN Take detailed notes of symptoms and medication View the cur...

Page 12: ...ature data to your phone up to 131 ft 40 m allowing you to monitor temperature without having to be near the user wearing the Fever Scout patch unobstructed view Note each Fever Scout patch must use i...

Page 13: ...harger are depleted please replace as a simultaneous set Patch Storage Charging LED Light ON Indicates the Fever Scout patch is charging The light will stay on for 15 seconds Flashing LED The charger...

Page 14: ...tion range 3 Blue side of the Fever Scout patch blocked by arm 1 Contact customer service at 408 663 6784 2 Recheck device s location or contact with the armpit 3 Keep this device attached for eight m...

Page 15: ...ft 40m with charger box relay and unobstructed view Accuracy 0 2 F 0 1 C between 98 6 F 102 2 F 37 C 39 C 0 4 F 0 2 C between 95 F 98 6 F 35 C 37 C 102 2 F 107 6 F 39 C 42 C Patch water resistance IP2...

Page 16: ...ct to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Ch...

Page 17: ...please contact your local waste disposal service This symbol on the product s and or accompanying documents means that used electrical and electronic equipment WEEE should not be mixed with general ho...

Page 18: ...charge ESD IEC 61000 4 2 6 kV contact 8 kV air Electrostatic discharge ESD IEC 61000 4 2 Floors should be wood concrete or ceramic tile If oors are covered with synthetic material the relative humidit...

Page 19: ...80 MHz to 2 5 GHz 3 V m Portable and mobile RF communications equipment should be used no closer to any part of Fever Scout including cables than the recommended separation distance calculated from t...

Page 20: ...ed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating Fever Scout NOTE 1 At 80 MHz and 800 MHz the higher frequency...

Page 21: ...itter For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmi...

Page 22: ...r use WEEE icon CE mark and noti ed body number Radio emission Polyethylene terephthalate window only Type BF applied part Catalog number Keep dry Temperature limit Authorized representative in the Eu...

Page 23: ...LBL 75 06 01 REV 01 Emergo Europe B V Molenstraat 15 2513 BH The Hague The Netherlands 10 C 50 F 40 C 104 F 0086 Printed in China...

Page 24: ...THANK YOU For choosing Fever Scout Manufactured by VivaLnk Inc 4655 Old Ironsides Dr 390 Santa Clara CA 95054 USA www feverscout com 408 868 2898...

Page 25: ...feature requires one phone the rst phone to connect to the Fever Scout patch and the other phone the second phone to log into the Fever Scout app with the same log in credentials Please refer to the...

Page 26: ...con in the menu and turning Cloud Monitoring on 2 Open the Fever Scout app on the second phone and log into the account using the same log in information as the rst phone 3 Select the pro le you would...

Page 27: ...37 5 C 35 9 C 37 6 C 36 4 C 37 8 C 36 4 C 38 0 C 35 8 C 36 9 C 36 4 C 37 6 C 35 5 C 37 5 C 35 6 C 36 3 C 35 2 C 36 9 C 35 9 C 36 7 C 96 6 F 98 0 F 95 9 F 99 5 F 97 5 F 100 0 F 96 6 F 99 7 F 96 4 F 99...

Reviews: