4
ENGLISH
BEFORE THE FIRST USE
After unit transportation or storage at low tem-
perature keep it for at least three hours at
room temperature before switching on.
There may be water spots in the air humidifier,
this is normal, as the unit has undergone fac-
tory quality control.
–
Unpack the unit, remove any stickers and pack-
aging materials that can prevent unit operation.
Check the unit for damages.
–
Before plugging the unit in make sure that your
home mains voltage corresponds to the unit
operating voltage.
–
The unit is intended for operation with AC sys-
tem and 50 or 60 Hz frequency. The unit does
not need any additional settings for operating
with the required nominal frequency.
Notes:
–
Use the air humidifier at the room temperature
from +10°С to +40°С, and relative humidity less
than 80%.
–
Water temperature should not 40°С
.
AIR HUMIDIFIER OPERATION
•
Remove the lid with a «mist» release opening (1)
from the tank (2).
•
Remove the tank (2) from the unit body (6).
•
Turn the tank (2) over, take the lid (3) off rotating
it counterclockwise.
•
Fill the tank (2) with the required amount of
water, insert the lid (3) in the water inlet and turn
it clockwise.
•
Place the filled tank (2) on the unit body (6),
install the lid (1) back to its place.
•
Insert the power plug into the mains socket.
•
Switch the air humidifier on by turning the knob
(8) clockwise, the power indicator (7) will light
up green.
•
Set the mist release intensity by turning the
knob (8).
•
If the water tank (2) is empty, the indicator (7)
will light up red.
•
Switch the air humidifier off turning the knob (8)
counterclockwise as far as it will go, the indica-
tor (7) will go out. Unplug the unit.
•
Fill the tank (2) with water, install it to its place
and switch the unit on.
•
After finishing the operation, switch the air
humidifier off by turning the knob (8) counter-
clockwise as far as it will go, the indicator (7)
will go out; after that remove the power plug
from the socket.
CLEANING AND MAINTENANCE
Warning! Always switch the air humidifier off
and unplug it before maintenance works or
cleaning.
•
Hard water causes the appearance of mineral
scale on the «sprayer» (5), on the inner parts
of the body and in the water tank (2); that leads
to improper operation of the air humidifier and
the appearance of white deposits on objects of
the interior.
•
To avoid this, it is necessary to clean the
«sprayer» (5) weekly and to change water in the
tank (2) as often as possible.
•
If you are not going to use the air humidifier for a
long time: pour out water from the tank (2) and
the process chamber (4) of the «sprayer» (5),
wash the tank (2), wash and clean the pro-
cess chamber (4) of the «sprayer» (5) and the
«sprayer» (5) itself, dry the unit thoroughly and
take it away for storage.
Weekly care
•
Once a week wash the water tank (2) and the
process chamber (4) of the «sprayer» (5) thor-
oughly with neutral detergent solution.
•
Then rinse them with water carefully.
•
Add 5-10 drops of the detergent on the
«sprayer» (5), wait for about 2-5 minutes.
Remove the deposits from the «sprayer» (5)
surface with a brush.
Note: As a cleaning agent for the «sprayer» (5) you
can use scale removers for kettles.
•
Clean the air humidifier body (6) with a soft
slightly damp cloth, and then wipe it dry.
•
Do not immerse the air humidifier body (6), the
power cord and the power plug into water or any
other liquids. Provide that no liquid gets inside
the air humidifier body (6).
•
Do not use solvents or abrasives to clean
the surface of the body (6) and the water
tank (2).
STORAGE
•
If you are not going to use the unit for a long
time and want to take it away for storage, make
sure that all its parts are dry, including the pro-
cess chamber (4) of the «sprayer» (5).
•
Do not store the unit with water in the tank
and in the process chamber (4) of the
«sprayer» (5).
•
Keep the air humidifier in a dry cool place away
from children and disabled persons.
IM VT-2341.indd 4
23.05.2019 17:12:56
Summary of Contents for VT-2341
Page 1: ...1 VT 2341 Humidifier 3 6 10 14 17 IM VT 2341 indd 1 23 05 2019 17 12 56...
Page 2: ...IM VT 2341 indd 2 23 05 2019 17 12 56...
Page 6: ...6 VT 2341 40 60 1 2 3 4 5 6 7 8 30 40 IM VT 2341 indd 6 23 05 2019 17 12 56...
Page 10: ...10 VT 2341 40 60 1 2 3 4 5 6 7 8 30 40 IM VT 2341 indd 10 23 05 2019 17 12 56...
Page 14: ...14 VT 2341 40 60 1 2 3 4 5 6 7 8 30 40 www vitek ru IM VT 2341 indd 14 23 05 2019 17 12 57...
Page 17: ...17 VT 2341 40 60 1 2 3 4 5 6 7 8 30 40 www vitek ru IM VT 2341 indd 17 23 05 2019 17 12 57...