Problem
Possible cause
Solution
The humidifier does not
operate
The unit is not plugged in
Plug the unit
The water tank is empty, the
indicator light (23) is red
Fill the water tank with water
Steam has an unpleasant
smell
New device – it is normal
Unscrew the lid of the water
tank and leave the unit for
several hours in a cool dark
place
Polluted water in the water tank
Clean the water tank
and fill it with pure water
Small intensity of steam
output
Polluted sprayer
Clean the sprayer
The remote control does not
operate
Obstacle between the remote
control and the sensor on the
unit
Remove the obstacle for proper
operation of the remote control
Large distance between the
remote control and the unit
Use the remote control in the
operating zone
Battery is discharged
Replace the battery
NOTE
Non-observance of rules for cleaning the unit parts from mineral deposits caused by
hard water may affect the overall performance of the unit.
In this case clean the unit and use filtered or distilled water in the future.
SPECIFICATIONS
Power supply: 220-230 V ~ 50 Hz
Power: 140 W
Water tank: 5 l
Water flow:
>=
400ml/h
Humidifying area up to 50m
2
Timer for 12 hours
Ions output: 2.000.000 ~ 3.000.000 ion /cm
2
Ozone output:
<=
0.05 PPM
Specifications subject to change without prior notice.
Service life of appliance - 3 years
GUARANTEE
Details regarding guarantee conditions can be obtained from the dealer from whom the
appliance was purchased. The bill of sale or receipt must be produced when making
any claim under the terms of this guarantee.
This product conforms to the EMC-Requirements as laid down by the Council
Directive 89/336/EEC and to the Law Voltage Regulation (73/23 EEC)