5
ENGLISH
–
If you want to use the aromatization func-
tion, press on the «Aroma» container (8) and
remove it. Add some drops of water-soluble
aromatic oil on the felt and install the «Aroma»
container (8) back to its place, pressing on it
until the clamp clicking.
Notes:
–
use water-soluble aromatic oils only;
–
if you are not going to use the aromati-
zation function, remove the felt from the
container (8), wash it and install back to its
place;
–
Insert the plug into the mains socket, you will
hear a sound signal and the digital indica-
tions of temperature (18) and relative humid-
ity (22) will appear on the control panel
display (1).
Note: - the room temperature and relative
humidity measurements are taken every 15 min-
utes.
–
Switch the unit on by touching the button (16).
You will hear a sound signal, and the unit will
be switched on and start operating at the
maximal «mist» release intensity; the display
will be glowing brighter and the «mist» release
intensity symbols (23) will appear.
Note: - regardless of the preset operating mode,
the display brightness decreases in 15 seconds
after you touch the control buttons for the last
time.
–
You can adjust the mist release direction by
turning the nozzle (3) in various directions.
–
To finish the air humidifier operation touch the
ON/OFF button (16) again.
–
Unplug the unit.
Notes:
–
the operation mode buttons on the control
panel (1) are sensory, you just need to touch
the button to switch the necessary operation
mode on.
–
the humidity level indications (22) may be
slightly different from the readings of another
hygrometer.
–
the humidity level indications depend on the
room temperature.
–
draughts or other air flows may significantly
affect the air humidity and temperature indi-
cations in the room.
–
the humidity sensor (10) is attached to the
power cord (11), make sure that the openings
on the sensor (10) body aren’t blocked with
foreign objects during the operation.
CONTROL PANEL (1) AND REMOTE
CONTROL (14) BUTTONS
ON/OFF button (16)
–
Press/touch the button (16) (
on the remote
control
) to switch the unit on and press/touch
the button (16) again to switch the unit off.
«Mist» release intensity setting panel (15)
–
After switching the air humidifier on you can
set the required «mist» release intensity. To
do this, touch the panel (15) in the right place
or draw your finger along the panel (15); the
«mist» release intensity will be shown on the
display with the symbols (23).
–
To set the required «mist» release intensity
with the remote control press the button (15).
Water tank lighting and ionization
on/off button (17)
–
Press/touch the button (17), the negative ion
generator will be switched on and the sym-
bol (20) will light up on the display.
–
To switch the ionization mode off press/touch
the button (17) again, the symbol (20) will go
out.
–
Touch the button/press and hold the button
(17) for 3 seconds, the water tank (2) light-
ing (7) will be switched on; to switch the water
tank (2) lighting (7) off touch the button/press
and hold the button (17) again for 3 seconds,
the lighting (7) will go out.
Room relative humidity setting button (24)
–
Consequently press/touch the button (24) to
set the desired level of relative humidity in the
room within the range from 30% to 75% with
the step 5%, the humidity level will be shown
on the display with the symbols (22).
–
After you set the required humidity level, the
digital indications (22) will flash 5 times, and
then the digital indications (22) of actual room
humidity will appear and the symbol «%RH»
will be flashing.
–
When the humidity reaches the preset level,
the air humidifier will be switched off; when
the humidity level decreases, the unit will be
switched on again, thus maintaining the pre-
set room humidity level.
–
To switch the selected humidity maintenance
mode off press/touch the button (24) until
the symbols «CO» appear on the display. The
humidity maintenance mode will be switched
IM VT-2336.indd 5
28.12.2016 17:46:12
Summary of Contents for 113621
Page 1: ...1 VT 2336 BK 3 8 14 20 Humidifier 26 IM VT 2336 indd 1 28 12 2016 17 46 11...
Page 2: ...IM VT 2336 indd 2 28 12 2016 17 46 12...
Page 9: ...9 www vitek ru 10 C 40 C 80 40 IM VT 2336 indd 9 28 12 2016 17 46 12...
Page 15: ...15 www vitek ru 10 C 40 C 80 40 IM VT 2336 indd 15 28 12 2016 17 46 13...
Page 21: ...21 www vitek ru 10 40 C 80 40 14 14 CR2025 IM VT 2336 indd 21 28 12 2016 17 46 13...
Page 25: ...25 1 1 1 220 240 50 30 5 5 300 35 2 3 2004 108 2006 95 IM VT 2336 indd 25 28 12 2016 17 46 13...
Page 27: ...27 www vitek ru 10 C 40 C 80 40 14 14 CR2025 IM VT 2336 indd 27 28 12 2016 17 46 14...
Page 31: ...31 1 1 1 220 240 50 30 5 5 300 35 2 5 IM VT 2336 indd 31 28 12 2016 17 46 14...