RAY-LG 35XX 

Version: 1.0

 

 

 

 

 

Blanking Routine during Door Opening / Partial Opening Function 

The output signal will remain off during the opening of the door until the 11

th

 beam is unobstructed (approx. 

500 mm  opening  height).  From  this  position  onwards  it  will  be  possible  to  reverse  and  close  the  door  in 

automatic  mode.  Successively  releasing  additional  light  beams  will  increase  this  partial  opening  position 

accordingly. During a later closing cycle, the monitored area and the smart blanking function will be limited 

to the previously saved partial opening height, higher positioned light beams will remain blanked. 

When the power supply of the RAY-LG is interrupted in a partial opening position, it is necessary to open 

the  door  higher  than  the  safeguarded  area  to  allow  the  system  to  undergo  an  automatic  initialization 

routine. 

 

Installation 

WARNING: 
Electrical and Mechanical Hazards

 

Electrical shock and unexpected door movement can cause serious injury or death. 

 

Follow all applicable safety measures 

 

Use only specific and approved tools 

 

If the RAY-LG must be adjusted, the main power supply must be switched off and marked as 

“out 

of service

”. 

Serious Health Risks -

 

Disregarding these warnings can result in serious injury or death

 

 

 

 

Never  scratch  or  paint  the  optical  lenses  because  it 

may  obstruct  the  light  path!  Do  not  drill  additional 

holes  into  the  profile.  Unpack  the  profiles  just  before 

installation in order to avoid damage. 

 

Do not bend or twist the edges! 

 

Oil  can  damage  the  cables.  Contamination  must 

always be avoided!

 

 

Chemical  can  damage  the  profile  and  optical 

characteristics. Contact must always be avoided! 

NOTICE: 
Mechanical Damage to the RAY-LG

 

 

Do not drill additional holes into the light curtain 

 

Do not drill through mounting holes 

 

Do not over-tighten the mounting screws 

 

Mount the edges on a flat surface 

 

Risk of damage -

 

Disregarding  this notice  can  lead  to damage to  the  sensor,  the door  controller  and /  or 

other devices

 

 

Summary of Contents for RAY-LG 35 Series

Page 1: ...ified Fulfils SIL 2 Without Testing OSE Output T V EC Type Examination Certified Direct Mounting in Door Tracks with Blanking Partial Opening Function High Detection Capability Due to Cross Beams Desi...

Page 2: ...ny alterations to the device by the buyer installer or user may result in unsafe operating conditions FRABA B V is not responsible for any liability or warranty claim that results from such manipulati...

Page 3: ...p to 2 5 m 8 2 ft in protection height When the infrared beams are interrupted the output sends a signal to the connected door control unit As soon as the detection area is clear again the output swit...

Page 4: ...surfaces near to or parallel to the detection area can cause reflections and interfere with the RAY LG s functions Keep a reasonable distance between the sensor edges and any reflective surface A self...

Page 5: ...g door starts at the topmost beam going downwards There are two ways to achieve blanking When the RAY LG is integrated inside or in this case matching holes need to be drilled behind the side guide th...

Page 6: ...allel to but not in line with the door panel in front of and behind the guide rail the descending door will not interrupt the active beams Figure 5 2 However blanking may still be required if any obst...

Page 7: ...Electrical and Mechanical Hazards Electrical shock and unexpected door movement can cause serious injury or death Follow all applicable safety measures Use only specific and approved tools If the RAY...

Page 8: ...on the sensor bars See Figure 6 2 3 In case of severe disturbances or direct sunlight mount the receiver on the opposite side 4 Mount the receiver bar into the guiding track next to the door control u...

Page 9: ...m Important Any unconnected not used wire must be separated and isolated Output When an obstruction is detected OBJECT DETECTED the RAY LG output changes after response time t2 When the object leaves...

Page 10: ...onnecting the gray wire to USP 10 to 30 VDC changes the output logic to DO dark on See Figure 9 If the gray wire is not connected floated the output logic changes to the OSE signal Gray wire Output lo...

Page 11: ...T the frequency starts again See Timing Diagram p 11 Test Input To fulfill EN ISO 13849 1 2015 the RAY LG with PNP NPN output must be tested by the door controller before each door closing cycle The R...

Page 12: ...wer up 3 Check the LED on both sensor bars power status 4 Test if the system is working correctly by letting the door open and close interrupting the light during the opening and closing process LED S...

Page 13: ...tective field is clear of interruption Clean the elements Make sure that the cables and sensor bars are located away from sources of electromagnetic interference Ensure that the emitter and receiver a...

Page 14: ...surface with a soft towel Make sure the profiles are securely fastened Check the mounting position cable routing and connection of the sensor Disposal Disposal should be done using the most up to date...

Page 15: ...Natural anodized aluminum Enclosure rating IP68 Cable IP67 Temperature range 40 C 60 C 40 F 140 F Electrical Supply voltage USP 10 30 VDC Current Consumption with 22 elements at 24 VDC 50 mA Output PN...

Page 16: ...D EN 12453 2017 E Device Applicable standards UL 325 2012 Synchronization and electrical connection Extention cable Length 10 m 33 ft Connector M8 4 pins A coded Diameter 3 5 mm 0 14 in Material PVC b...

Page 17: ...LG 35XX Page 17 RAY LG 35XX Version 1 0 Dimensions Measurements for 22 elements all dimensions in mm Figure 10 RAY LG 3522 Dimensions mm Measurements for 20 elements all dimensions in mm Figure 11 RAY...

Page 18: ...c EN 13849 1 2008 Performance Level of the Control Unit c acc EN 13849 1 2008 Please pay attention to the operating manual of the control unit Control Unit OSE C 5024 Supply Voltage USP 24VAC DC Dimen...

Page 19: ...manufacturing job number eeeee employee number responsible for final test cccccc incremental number Technical Instruction valid from year of manufacture 2019 Disclaimer FRABA B V all rights reserved...

Reviews: