1. The modular system

   

2. First use

 

3. Scope of supply/system solutions

2.2 Set up sintering unit

• 

Please ensure that the following conditions are met.

Please note:

• 

Set the device up in a dry, heated room. The distance between the sintering unit and the next wall should be at least 50 cm.

• 

When the temperature is below 15°C (e.g., after transport), leave the device to stand for approx. 60 minutes at room 
temperature before using it for the first time.

• 

Ensure that the unit is installed on a heat-resistant and non-flammable surface.

• 

The radiation and heating of the device is within a non-hazardous range. Nevertheless, heat sensitive surfaces of furniture 
and veneers may become somewhat discolored over time, due to the constant influence of heat. Therefore, maintain a 
minimum distance of 50 cm.

• 

Avoid direct sunlight on the device.

• 

Do not place flammable objects near the device.

• 

Do not place the control unit directly in the area of heat radiation of the sintering chamber.

• 

The distance between the sintering furnace and the control unit must be at least 20 cm.

• 

Set up the device in such a way that the main switch can be easily accessed and the power supply cable can be easily 
disconnected. Before using the device for the first time, please read the corresponding operating manual for the control unit.

• 

An electrical connection to distribution outlets with an extension is not permitted.

2.3 Status display

Blue:

 Firing program active

Red

: Error – blinking mode

Blinking 

green

/

red

: Update is running

• 

When the unit is not in use, move the lift plate upwards and switch off the unit from the main switch.

• 

Closing the sintering chamber protects the insulation and prevents moisture absorption.

2.4 Switch off sintering unit and control unit

Summary of Contents for ZYRCOMAT 6100 MS

Page 1: ...COMAT 6100 MS VITA perfect match Operating manual Date of issue 02 19 VITA Farbkommunikation VITA Farbkommunikation VITA shade control VITA shade reproduction VITA shade communication VITA shade deter...

Page 2: ...d safe operation To be able to use the sintering furnace safely and effectively please read these operating instructions completely before use This operating manual must always be kept close to the de...

Page 3: ...Sintering chamber insulation 16 5 Additional information 5 1 VITA warranty and consumer protection 17 5 2 Update messenger 17 5 3 Spare parts 17 5 4 Patents and trademarks 17 5 5 Hotline and support...

Page 4: ...4...

Page 5: ...ntrolling two or more VITA furnaces using the VITA vPad excellence you will need a VITA SWITCHBOX with connecting cable The VITA SWITCHBOX is an adapter for connecting two to four firing devices to th...

Page 6: ...nd two part Lift plate Connection for VITA vPad comfort VITA vPad excellence VITA SWITCHBOX Cooling table Mains power supply connection Main switch Status display Note What High quality sintering furn...

Page 7: ...sintering dish is set at a maximum of 40 units Whenever you open the furnace always ensure that all doors and windows are closed so that the sintering dish is not exposed to a cold air draft 1 2 Acces...

Page 8: ...8...

Page 9: ...am for the first time please set the status display insert the metal ring turn it clockwise and let it engage Then insert the two part sintering base Please note Please start the program only if the s...

Page 10: ...inimum distance of 50 cm Avoid direct sunlight on the device Do not place flammable objects near the device Do not place the control unit directly in the area of heat radiation of the sintering chambe...

Page 11: ...ply system solutions 4 Technical data Information Article Scope of supply VITA ZYRCOMAT 6100 MS 1x Sintering stand 2x Sintering dish 1x Tongs 1x 150g ZrO2 spheres 1x Status display light bar 1x Connec...

Page 12: ...n the VITA Linearguide 3D MASTER for example Various geometries translucency and chroma levels of VITA YZ blanks are available for CAD CAM fabrication For manual coloring of the milling results use th...

Page 13: ...t always disconnect it from the mains current by unplugging the power plug Residual voltage After the back plate has been removed a residual voltage of up to 400 V may still be present in components i...

Page 14: ...top cover of the sintering chamber as well as the opening in the back cover must not be covered or closed The unit may not be used without the fan Authorized modes of operation The insulation of the s...

Page 15: ...tes An error message is displayed once power is restored Obstruction sensor The vertical movement of the lift plate is controlled by computer Any trapped objects are detected and the drive is switched...

Page 16: ...he gray oxide layer of the heating elements is discovered during this visual inspection it is imperative to carry out a cleaning firing The cleaning firing builds up the oxide layer and gives the surf...

Page 17: ...es e mailed to you an option to register is provided at www vita zahnfabrik com update messenger 5 3 Spare parts Spare parts must comply with the technical requirements specified by the manufacturer T...

Page 18: ...18 NOTES...

Page 19: ...VITA product solutions you can contact our technical specialists Mr Ralf Mehlin or Mr Daniel Schneider Phone 49 0 7761 56 22 22 Fax 49 0 7761 56 24 46 8 00 a m to 5 00 p m CET Email info vita zahnfab...

Page 20: ...e use with regard to its suitability for the intended area of applications We cannot accept any liability if the product is used in conjunction with materials and equipment from other manufacturers th...

Reviews: