background image

VISTEK V165X serial digital 
video router module 

 

 

 

HU-V165X

 

 

 

       

5

 

 

 

REF 
 

 

The reference input is an analogue video signal of either 1Vp-p video or upto 4Vp-p mixed sync pulses. The 
signal is passed through the rear module and terminated in 75 Ohms on the input router module.

 

 

 

SD (OUT) & SD1-8 (OUT) 
 

 

The  outputs are driven directly through  the rear module from the input or output router module at 75 Ohm 
impedance.

 

 
MON (OUT) 

 

 

The  monitoring  output  is  driven  directly  through  the  rear  module  from  the  input  router  module  at  75  Ohm 
impedance. This output monitors the output busses of the crosspoint ic and not the inputs to the crosspoint.

 

 

DART Remote Control 
 

 

The  DART  control  interface  is  picked  up  by  the  input  rear  module  from  the  rack  and  routed  into  the  input 
router module. 
 

2.2 

Hardware 

 
The  figure  below  shows  diagramatically  the  input module, which contains all the control hardware and  link 
selectable  variations.  Not  all  components  are  fitted  in  every  variant,  (see  text  for  details).  The  8  Output 
module has no links and is therefore not shown.  
 
 
 
 

 
 
 
 

2.2.1 

Switch and Link Settings 

 

R102 & R103 

 

 

These two resistors are used to control the routing of the signal on input eight to determine if the reference is 
used or SDI input eight. The modules are shipped in the following configurations:- 
V1651   

R103   

Reference Input. 

V1652   

R102   

SDI Input eight. 

V1653   

R103   

Reference Input. 

V1654   

R102   

SDI Input eight. 

 
 

 

 
 
 

F

R

O

N

T

 P

A

N

E

EC2 

SW11 

a b c

a b c 

LK

LK2 

SW12 

  R

E

A

R

 C

O

N

N

E

C

T

O

R

 

R102
R103

Summary of Contents for V1651

Page 1: ...1 VISTEK V165X SERIAL DIGITAL VIDEO ROUTER MODULE USER GUIDE www pro bel com...

Page 2: ...uter module 2 Issue 1 Contents 1 INTRODUCTION 3 1 1 Description 3 2 INSTALLATION 4 2 1 Rear Panel Connections 4 2 2 Hardware 5 2 2 1 Switch and Link Settings 5 3 OPERATION 9 3 1 Front Panel Indication...

Page 3: ...is user selectable and may be field or frame based The routers are all provided with front panel controls and indicators All the modules are provided with the required interface logic for the Dart re...

Page 4: ...by 0 5W SD1 8 IN The Serial Digital Inputs are passed straight through the rear module and terminated in 75 Ohms on the main module Input 8 on the V1652 and V1653 is shared with the reference input a...

Page 5: ...Remote Control The DART control interface is picked up by the input rear module from the rack and routed into the input router module 2 2 Hardware The figure below shows diagramatically the input modu...

Page 6: ...nce timing is taken from the REF input but in its absents the router reverts to using the currently selected output or the free running clock The link is also used on the V1652 and V1653 to instruct t...

Page 7: ...the reference upto the selected delay See table Approximate selected delays wrt selected reference SW12 Approx Delay us 2 3 4 143Mbits s 177Mbits s 270Mbits s 360Mbits s 0n 0n 0n 179 0 7 225 0 5 147 0...

Page 8: ...r ic Switch 7 on EDH Fail Sets the fail condition to occur when multiple EDH errors are detected An error condition will be set if 3 fields containing EDH errors are detected within 32 fields and clea...

Page 9: ...ndicates that a 177Mbit s ITU R Rec 601 serial composite video source is selected The EDA lamp indicates an error in the Serial Video Signal which was detected prior to this unit Error detected alread...

Page 10: ...10 Issue 1 REM V 270 360 143 177 EDA EDH Rem Local Auto Ref Select V1651 REM V 270 360 143 177 EDA EDH Rem Local Source 1 2 3 4 5 6 7 8 V1652 REM V 270 360 143 177 EDA EDH Rem Local Source 1 2 3 4 5 6...

Page 11: ...nal is locked in the reclocking ic If no indicators are on then the signal has not locked up in the reclocker EDA EDH These indicators are used to display Errors that are detected within certain check...

Page 12: ...tput is prohibited automatically Destination 1 8 These are illuminated push buttons and allow selection of the destination bus for the local control panel on the V1654 only These button remain active...

Reviews: