Description 

 
The V165X Serial Digital Video Router Module provides a platform on which several different types of router 
may be built. All the variants can handle the four main video standard frequencies of 143, 177, 270 and 360 
Mbits/s. The outputs are fully re-generated. 
 
The range consists of :- 
 
The V1651 2x1 SDI router with automatic signal error detection and changeover. 
The V1652 8x1 SDI router. 
The V1653 8x1 SDI router with synchronous switching. 
The V1654 8x8 SDI router with Output monitoring. 
 

 

All the routers can be fed with an analogue external reference signal, but this reduces the 8x1 routers to 
7x1's due to the limited rear panel space. If the external reference is not fitted the switching reference will be 
taken from the currently selected output, so vertical interval switching will be maintained between sources of 
the same relative timings. The switching line used is user selectable and may be field or frame based. 

 

 
The routers are all provided with front panel controls and indicators.  All the modules are provided with the 
required interface logic for the Dart remote control system and also a simple remote panel interface. (See 
V1650 Remote Control Manual). 
 
The V1651, 2 & 3 modules are 3U high cards and are designed to fit in the V1601 or the V1603 racking 
systems. The V1654 is also 3U high modules, but is double width, so will only fit in the V1603 rack. 
 
The V1651 and V1653 are designed to have clean switching between the sources. The routers achieve this 
by timing the new source as close to the reference as possible, before switching. The reference is obtained 
from either the External Reference input (I/P 8), or if not present the currently selected source. (The V1651 
may have its clean switching turned off if a reference is not available.) 
 
Due to the sources having differing clock phases it is only possible to synchronise the sources within one 
clock cycle, so if the reference is taken from the sources rather than an external reference the delay through 
the router can progressively change as sources are selected. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for V1651

Page 1: ...1 VISTEK V165X SERIAL DIGITAL VIDEO ROUTER MODULE USER GUIDE www pro bel com...

Page 2: ...uter module 2 Issue 1 Contents 1 INTRODUCTION 3 1 1 Description 3 2 INSTALLATION 4 2 1 Rear Panel Connections 4 2 2 Hardware 5 2 2 1 Switch and Link Settings 5 3 OPERATION 9 3 1 Front Panel Indication...

Page 3: ...is user selectable and may be field or frame based The routers are all provided with front panel controls and indicators All the modules are provided with the required interface logic for the Dart re...

Page 4: ...by 0 5W SD1 8 IN The Serial Digital Inputs are passed straight through the rear module and terminated in 75 Ohms on the main module Input 8 on the V1652 and V1653 is shared with the reference input a...

Page 5: ...Remote Control The DART control interface is picked up by the input rear module from the rack and routed into the input router module 2 2 Hardware The figure below shows diagramatically the input modu...

Page 6: ...nce timing is taken from the REF input but in its absents the router reverts to using the currently selected output or the free running clock The link is also used on the V1652 and V1653 to instruct t...

Page 7: ...the reference upto the selected delay See table Approximate selected delays wrt selected reference SW12 Approx Delay us 2 3 4 143Mbits s 177Mbits s 270Mbits s 360Mbits s 0n 0n 0n 179 0 7 225 0 5 147 0...

Page 8: ...r ic Switch 7 on EDH Fail Sets the fail condition to occur when multiple EDH errors are detected An error condition will be set if 3 fields containing EDH errors are detected within 32 fields and clea...

Page 9: ...ndicates that a 177Mbit s ITU R Rec 601 serial composite video source is selected The EDA lamp indicates an error in the Serial Video Signal which was detected prior to this unit Error detected alread...

Page 10: ...10 Issue 1 REM V 270 360 143 177 EDA EDH Rem Local Auto Ref Select V1651 REM V 270 360 143 177 EDA EDH Rem Local Source 1 2 3 4 5 6 7 8 V1652 REM V 270 360 143 177 EDA EDH Rem Local Source 1 2 3 4 5 6...

Page 11: ...nal is locked in the reclocking ic If no indicators are on then the signal has not locked up in the reclocker EDA EDH These indicators are used to display Errors that are detected within certain check...

Page 12: ...tput is prohibited automatically Destination 1 8 These are illuminated push buttons and allow selection of the destination bus for the local control panel on the V1654 only These button remain active...