3.2.2 If F1 is not set to NONE in Plugin Configuration Table, action in 3.2.1 will execute predefined
Mach3 OEM button, Custom Button, or Custom Macro.
3.3 GOTOZ and F2 button
3.3.1 While pressing and holding F2 button, LCD displays the button function, and press the EN side
button
to execute GoToZero function.
3.3.2 If F2 is not set to NONE in Plugin Configuration Table, action in 3.3.1 will execute predefined
Mach3 OEM button, Custom Button, or Custom Macro.
3.4 COORD and F3 button
3.4.1 While pressing and holding F2 button, LCD displays the button function, and press the EN side
button
to select different coordinate or fixture. Selection sequence is G54 (fixture 1), G55 (fixture
2), G56 (fixture 3), G57 (fixture 4), Machine Coordinate, and Distance to Go.
3.4.2 If F3 is not set to NONE in Plugin Configuration Table, action in 3.6.1 will execute predefined
Mach3 OEM button, Custom Button, or Custom Macro.
When pressing and holding a function button, user defined function name will display on LCD.
Maximun16 characters can be used to name a function in Plugin Configuration Table
.