7
Xero Twin P/L
a
To
tal length (with infeed and end cap)
3000
/118" / lt
o
± 1
/ ± 0.0
39"
ø 4.6
0.181"
ø 5.6
0.220"
ce
d
e
f
b
b
optional
e
e
mm
in
a
b
c
d
e
f
80
2
27
22
50
9.5
3.150
0.079
1.063
0.866
1.969
0.374
1/2019 (US)
End caps must be fitted on profile with conductor rail.
Take care to assemble the profile in the correct direction (power supply
must be below).
Power supply is available via the left profile slot. The right-hand side is
fitted with a non-powered profile.
Depending to your local regulations, a conduit must be used for the
primary side of the driver. Check this before installation.
It must be ensured that access to the driver is possible for inspection and
subsequent servicing.
Dimensions and distances of holes
All fastening points have to be used in event of maximum loads!
The electrical components and the end cap must be removed before shortening the profile. Always shorten a profile from the top side and
burr the edges. Make sure that all shavings are removed from the profile. The electrical components and end cap must be fitted back onto
the profile.
Shortening a profile