3
Xero Twin P/L
349-060.19
349-061.19
red
6.
1
0.240"
4.2
0.165"
349-140.19 (90 W)
NV (24 V)
L = 500 mm
/ 19.685"
ø
7.7 mm
0.303"
120 V
L
=
1500 mm
/ 59.055“
1/2019 (US)
Xero Twin P/L has a CE label and a UL certificate for U.S. and Canada.
Converter 24 V for electrified profile
Converter with input voltage 120–240 V / mains frequency: 50–60 Hz electronic protection
against overload, overheating and short-circuit.
- Housing temperature max. 75 °C / max. 167 °F
- Nominal output voltage: 24 V / SELV
- Power supply with permissible nominal current of max. 4 A
- Connection cable from converter to infeed unit
500 mm
/19.685"
- Class 2
NOTICE! If dimmers are to be used, electronically controlled, low-voltage dimmers must be
installed!
TECHNICAL DATA SHEET XERO TWIN P/L
Xero Twin P/L electrification in detail: conductor rail with power supply, integrated into system support profile.
Correct functioning and safety are guaranteed when properly used. No liability is accepted in event of improper use. Product safety
is based exclusively on the use of original Xero Twin P/L accessories from Visplay.
No alterations may be made, for safety reasons; the only exception is the shortening of profiles from the upper side.
The safety instructions of the assembly instructions must be followed as well as the instructions on the labels of the individual parts.
The indicated nominal current (A) may not be exceeded.
In event of improper use or cleaning with liquids, a risk of an electric shock exists due to possibly exposed live parts. Always
disconnect from power before cleaning or servicing.
If rails or adapters exhibit visible signs of damage, disconnect them immediately and inform your service technician.
Product safety
Single power adapter 24 V
Single power adapters can be used with the Xero L P/L and Xero Twin P/L systems. Low
voltage lighting may only be connected by trained personnel.
If multiple adapters and appliances will be used, their total power consumption may not
exceed the specified nominal current or fuse rating. The permissible nominal voltage and
nominal current are also limited according to the adapters used (see printed label and safety
information).
Permissible nominal current max. 4 A.
Only use Xero Twin P/L system accessories! Do not use any other parts.
The user is responsible for ensuring that any connected equipment is electrically, mechanically and thermally compatible with the conductor rail.
Please make sure that the inspector has access to the driver