APPENDIX A. Specifications
76
D-304762 PowerMaster-10/30 G2 Installer's Guide
PowerMaster-10 G2
PowerMaster-30 G2
(2) 7.2V 1300 mAh, rechargeable NiMH
battery pack, p/n GP130AAH6BMX,
manufactured by GP only. For UL Listed
product, use this battery only.
(3) 9.6V 1800 mAh, rechargeable NiMH
battery pack, p/n GP180AAH8BMX,
manufactured by GP or equivalent.
(4) 9.6V 2200 mAh, rechargeable NiMH
battery pack (special order) or equivalent.
Note:
Some panel variants use 7.2V 1800
mAh, rechargeable NiMH battery pack, p/n
GP180AAH6BMX, manufactured by GP only
(available by special order).
Caution!
Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Note:
For compliance with CE standards the
battery backup period must be at least 12 hours.
Time to Charge
80 % (
∼
13 Hrs)
80 % (
∼
30 Hrs) for all battery types
Optional Backup
Battery Pack
See "Backup Battery Options" above
See "Backup Battery Options" table above
Time to Charge
(optional backup
battery pack)
80 % (
∼
24 Hrs)
NA
Wired Detectors
Total (Sum)
Current
NA
36* mA max.
Site External Siren
Current (EXT)
NA
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
Site Internal Siren
Current (INT)
NA
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
*
Total PowerMaster-30 G2 output current
(of INT & EXT sirens, PGM output and
detectors) cannot exceed 550 mA.
PGM
Current sink to control panel GND 100 mA
max.
Max. external DC v30 VDC
Current sink to control panel GND 100 mA
max.
Max. external DC v15 VDC
High Current /
Short Circuit
Protection
NA
All outputs are protected (automatic reset fuse)
A4. Communication
PowerMaster-10 G2
PowerMaster-30 G2
Communication
PSTN; GSM; GPRS; IP (for future use)
PSTN; GSM; GPRS; IP (for future use)
Built-in Modem
300 baud, Bell 103 protocol
300 baud, Bell 103 protocol
Data Transfer to
Local Computer
Via RS232 serial port
Via RS232 serial port
Report
Destinations
2 Monitoring Stations, 4 private telephones
2 Monitoring Stations, 4 private telephones
Reporting Format
Options
SIA, Contact ID, Scancom, SIA IP, Visonic
PowerNet.
Note:
For UL Listed product, the
communication formats used are SIA and
Contact ID.
SIA, Contact ID, Scancom, SIA IP, Visonic
PowerNet.
Note:
For UL Listed product, the
communication formats used are SIA and
Contact ID.
Pulse Rate
10, 20, 33 and 40 pps - programmable
10, 20, 33 and 40 pps - programmable
Message to Private
Phones
Tone
Tone or voice
Ring Detection
The unit does not support ring detection without
DC voltage present on the telephone lines.
The unit does not support ring detection without
DC voltage present on the telephone lines