![Visonic PowerMaster-10 G2 Quick User Manual Download Page 55](http://html.mh-extra.com/html/visonic/powermaster-10-g2/powermaster-10-g2_quick-user-manual_1032851055.webp)
5. PROGRAMMING
D-304762 PowerMaster-10/30 G2 Installer's Guide
55
Enter "
7:BROADBAND
", select the menu to configure (see guidance above and in section 5.6.1), then refer to the
table below for configuration instructions.
Option
Configuration Instructions
DHCP Client
Define whether to obtain an IP address automatically using a DHCP server or to enter an
IP address manually.
Options:
Disable
(default)
; Enable.
MANUAL IP
Manually enter LAN parameters.
→
→
→
→
IP ADDRESS
Enter the IP address of the Broadband Module
→
→
→
→
SUBNET MASK
Enter the subnet mask used with the IP address.
→
→
→
→
DEFAULT GW
Enter the default gateway of the Broadband Module.
Note:
If DHCP Client is set to Enable, the entries for IP ADDRESS, SUBNET MASK and
DEFAULT GW will be ignored.
RESET MODULE
Determine whether to reset the broadband module (REBOOT) or to reset all broadband settings –
does not reset Monitoring Station IP settings. (FACTORY DEFIN.).
5.7 PGM Output
5.7.1 General Guidance
The "
05:OUTPUTS
" menu enables you to select events/conditions under which the PGM (programmable) output will
function and to select the internal siren or STROBE light (that will be activated according to system programming).
1
05:OUTPUS
⋅ ⋅ ⋅
PGM DEVICES
⋅ ⋅ ⋅
PGM DEVICE 01
⋅ ⋅ ⋅
MENU you wish
Enter "
PGM DEVICE 01
", select the menu you wish to configure (see guidance above and in section 5.2), and then
refer to the table in section 5.7.5 for configuration instructions.
Note:
PGM not to be enabled in UL Listed Product.
5.7.2 Open Collector States
The PowerMaster provides an open collector output (active low) for control:
ON state (pulled to ground) = 0
OFF state:
no pullup = float
with pullup to Vcc = 1
5.7.3 Configuring a PGM device
Define which factors, including any combination of factors, will determine the PGM output.
5.7.4 Entering Daytime Limits
05:OUTPUS
⋅ ⋅ ⋅
PGM DEVICES
⋅ ⋅ ⋅
LOCKOUT TIME
Enter the "
LOCKOUT TIME
" menu and enter the daytime limits through which the PGM device will turn off, even when
the associated sensors are triggered.
5.7.5 PGM Output Configuration
Option
Configuration Instructions
PGM: BY ARM AWAY
PGM: BY ARM HOME
PGM: BY DISARM
Determine to activate the PGM output upon arming
Away / Home / Disarm
.
Options:
disable
(default)
; turn ON; turn OFF; activate PULSE
.
PGM: BY MEMORY
Determine to activate the PGM output upon registration of an alarm in the memory. The
output will restore to normal upon memory clearing.
Options:
disable
(default)
; turn ON; turn OFF; activate PULSE
.
Note:
In Soak Test mode
2
and when BY MEMORY is enabled, the PGM will not be
activated.
1
In PowerMaster-10 G2, this is always available. In PowerMaster-30 G2, this is optional only when the expansion module is installed.
2