background image

D-301436 

2.

 Drill 3 holes on mounting wall and insert 3 screws 

into the bracket slots then tighten screws to 
secure bracket (see Figure 7b). 

 
3.

 With the bracket mounted on the wall, position the 

Base Unit so that the top two hangers of the 
bracket are fitted onto their respective holes 
followed by the bottom hanger (see Figure 7c). 

Note:

 Please use a Philips flat pan head 

screwdriver type AB P/N 6x1 in. and wall plug 
anchors. 

 

 

Figure 7b 

 Wall Mounting – Mounting Bracket on Wall 

 

For wall mounting

rotate the bracket 180

º

Correct

bracket

position

 

Figure 7a

 

Wall Mounting – Correct Positioning of Bracket

 

HOLES FOR

HANGERS

 

Figure 7c

 

Wall Mounting

 

– Attaching Cabinet to the Bracket

 

USING YOUR SYSTEM 

Using your Base Unit 

Your Base Unit is the communication center of 
your system. When your pendant transmitter or 
optional fall-detector/smoke detector signals the 
Base Unit, the Base Unit contacts your Monitoring 
Center to report the emergency event. 
Your Base Unit includes the following buttons. 

 

EMERGENCY (red)

 – When pressed, an 

emergency alarm is reported to the Monitoring 
Center and a two-way voice communication is 
opened between the unit and the Monitoring 
Center. 

 

CALL (gray)

 – When pressed, a non-emergency 

message is reported to the Monitoring Center and 
a two-way voice communication is opened 
between the unit and the Monitoring Center. 

 

CHECK (gray) 

– This button should be pressed to: 

-

 Answer Incoming Calls. When the phone rings, 

pressing this button activates the speaker 
phone. 

Acknowledge Programmed Reminders, such 

as confirming you have taken medication. 

-

 Change the status of the unit to HOME or 

AWAY. To do this, press this button 
continuously for 5 seconds. 

-

  Announce Time – press this button for 1 second. 

 

Direct Link (white)

 – The Base Unit includes 3 

buttons for unique direct link, as described in the 
next section.

 

Using your Pendant Transmitter 

The pendant transmitter can be used to initiate an 
emergency call and also to answer incoming calls. 

 

Pendant Activation

 - Your pendant transmitter 

lets you signal to the Base Unit from anywhere in 
your home when you need emergency assistance. 
You should wear your pendant transmitter 
whenever you are at home even in the shower or 
bath. Your pendant transmitter is waterproof. 

Summary of Contents for AMBER CLASSIC

Page 1: ...D 301436 1 AMBER CLASSIC AMBER CLASSIC X Wireless Emergency Response System User s Guide ...

Page 2: ... is automatically recharged What s Included Before you begin to set up your system make sure you have all the necessary components Base Unit 110V 12V transformer For USA use cat OH 48109AT Wrist Pendant transmitter MCT 212 supplied with necklace not evaluated by UL Additional Accessories Optional Wrist Pendant transmitter MCT 211 supplied with necklace UL listed Battery operated smoke detector MCT...

Page 3: ...ER Green Normally ON indicating that your system is properly connected to the power outlet TROUBLE Red Normally OFF If LED flashes there is a problem with the Base Unit or one of the devices described on the display of AMBER CLASSIC STATUS Yellow Normally OFF which indicates the system is in HOME mode FLASHES when unit is in AWAY mode Special Functions Calling for help by using an emergency pendan...

Page 4: ...isonic representative for further details Step 2 Rotate the Antenna on the Base Unit Figure 3 The antenna helps your pendant s and detector s communicate with your Base Unit Rotate the antenna to its utmost vertical position Step 3 Connect the Base Unit to your Telephone Line Figure 4 The Base Unit communicates with your Monitoring Center through your telephone line 1 Locate the phone jack on your...

Page 5: ...n electrical power is supplied to the AMBER CLASSIC X the green light on the front panel illuminates Step 5 Base Unit is now connecting you to the Monitoring Center After installation a Monitoring Center representative will begin speaking to you When your Monitoring Center representative answers you can hear them talking to you through the Base Unit You can talk to the representative by speaking o...

Page 6: ...hen pressed an emergency alarm is reported to the Monitoring Center and a two way voice communication is opened between the unit and the Monitoring Center CALL gray When pressed a non emergency message is reported to the Monitoring Center and a two way voice communication is opened between the unit and the Monitoring Center CHECK gray This button should be pressed to Answer Incoming Calls When the...

Page 7: ... Yellow Off Away mode On Home mode Flashes Active reminder Trouble messages are shown on the Base Station display AMBER CLASSIC only until they are resolved Pressing the CHECK button confirms the trouble condition and cancels the beeps The Base Unit continues to transmit trouble messages every eight hours until the problem is resolved Changing System Status When the user wants to leave the premise...

Page 8: ...es the fall detector to its upright position the unit will announce Fall Device Upright System OK In the Event that No Activity is detected Motion Detector Transmitter Optional The motion detector and door contact transmitter are used to monitor the user s activity If no activity is detected by the enrolled transmitter s during a pre defined amount of time the AMBER CLASSIC AMBER CLASSIC X will re...

Page 9: ...ou must then press the pendant transmitter whereby the unit will announce and display AMBER CLASSIC only Test Complete MAINTAINING YOUR SYSTEM When a Pendant s Battery is Low When a pendant transmitter s button is pressed and its battery is low the pendant transmitter flashes rapidly several times per second and the red light on the Base Unit flashes continuously until the pendant s battery is rep...

Page 10: ...tative You hear strange tones when using the phone Your Base Unit is trying to call your Monitoring Center Hang up so your system can report a problem to the Monitoring Center When it finishes you can use the phone You hear noise interference when using your cordless phone The cordless phone might be picking up noise interference from the Base Unit If the cordless phone s base is connected to the ...

Page 11: ...an evacuation plan Draw a floor plan of your home displaying two possible exit areas of each room including windows Don t forget to mark the location of every installed smoke detector Test all smoke detectors periodically this must be performed in a qualified testing laboratory to ensure their serviceability Replace batteries as required Make sure that everyone understands the escape plan and is a...

Page 12: ...ESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL AND OR BODILY INJURY AND OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION However if the Manufacturer is held...