TVD Series Multifunction Scale Scale Technical Manual
The function is not valid when one enters a lower limit greater than
the upper limit.
When lower limits are the same with upper limits,display only shows
one set value.
5.8 Accumulation
TVD can set to accumulate manually by pressing
key or
automatically.Before operation scale should be stable and return to zero,
accumulation available only when weight more than 20d
To set the accumulation function to turn on, select the parameter ACC>ON
Note: Accumulation function can operate only in weighing mode
.
5.8.1 Manual Accumulation
In the normal weighing mode, ensure display is zero and stable indicator is on.
1 Place the items on the platform and press
key, when the display get
stable
2 Display will be show ACC 1 and will show the total of the accumulation
3 The data will be sent to printer or PC if connected with printer or computer
4 Remove the weight from the pan for to get display zero and stable for the
next accumulation.
5 Scale should be get stable and zero for the next accumulation.
It can continue 99 operations or until to reach the maximum value of display.
5.8.2 Recall Memory
Press
key, when the display in the normal weighing mode, display will be
show the accumulation times and will show the total values. These display will be
show only two seconds.
5.8.3 Memory Clear
To clear the memory, press
key to view and press
key
during the
accumulation displayed. Display will be show normal display , all accumulation
memory cleared from the memory