background image

Version # 2                                                                                                               

Smart Body Scale - User Guide 

1        Table of Contents 

1.1

 

Introduction 

1.2

 

Intended Use 

1.3

 

Safety Information 

1.3.1

 

Operating the device - Warnings 

1.3.2

 

Cautions 

1.4

 

Before taking a Measurement 

1.4.1

 

Select the weight Unit 

1.4.2

 

Position the Body Scale 

1.4.3

 

Automatic shutdown function 

2

 

Operating Instructions 

2.1

 

Know your NantLife Smart Body Scale 

2.2

 

Unit Display 

2.3

 

Display Symbols 

2.4

 

Battery Installation 

2.5

 

Battery Replacement 

2.6

 

Using the device 

2.7

 

Taking a measurement 

2.8

 

Bluetooth Activation & Pairing 

2.9

 

Data transmission 

2.10

 

Using the memory function 

2.11

 

Using the software 

2.12

 

Evaluation by your care provider 

3

 

Care and Maintenance 

3.1

 

Cleaning 

3.2

 

Maintenance 

4

 

Troubleshooting 

4.1

 

Troubleshooting tips 

5

 

FCC statement 

6

 

CE mark 

7

 

Warranty 

8

 

Specifications 

9

 

Manufacturer 

10

 

Manufacturer’s electromagnetic guidelines 
 

 

 

 

 

User Manual 

Smart Body Scale  

Model Name

BS4.0  Brand NameNantLife 

                         FCC ID: OXJBS40

Summary of Contents for BS4.0

Page 1: ...nit Display 2 3 Display Symbols 2 4 Battery Installation 2 5 Battery Replacement 2 6 Using the device 2 7 Taking a measurement 2 8 Bluetooth Activation Pairing 2 9 Data transmission 2 10 Using the memory function 2 11 Using the software 2 12 Evaluation by your care provider 3 Care and Maintenance 3 1 Cleaning 3 2 Maintenance 4 Troubleshooting 4 1 Troubleshooting tips 5 FCC statement 6 CE mark 7 Wa...

Page 2: ...Home with the HBox b Mobile Health with your Bluetooth enabled smartphone The NantLife Smart Body Scale comes with the following components Monitor with LCD display ON OFF button Weight Mode Switch button lb pounds kg Kilograms 4 extra carpet feet Maximum capacity 180kg 396lbs Step On feature Instruction Manual printed in English French and Spanish Warranty card Thank you for your trust we are ava...

Page 3: ...vice Basic safety precautions should always be observed especially when the Body Scale is used on or near children and disabled persons Do not under any circumstances use the device in the bath or the shower If however liquid get into the device you must remove the batteries immediately and refrain from further use Contact our service department see front cover The device may not be used near a nu...

Page 4: ...ng measurements To monitor progress compare weight and body fat percentage taken under the same conditions over a period of time Note An accurate reading will not be possible if the soles of your feet are not clean or if your knees are bent or you are in a sitting position Stand straight 1 4 1 Select the weight mode Select the weight unit you want to use by using the switch on the back of the scal...

Page 5: ...nsertion 1 Press the indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AAA size batteries so the positive and the negative match the polarities of the battery compartment 3 Replace the battery cover 2 5 Battery Replacement image of low battery indicator When the low battery indicator appears on the display screen turn off the monitor and remove all th...

Page 6: ...martPhones Step 1 First set up your mobile phone to receive data by Bluetooth see your mobile phone user guide If your phone is already activated go to step 2 Step 2 Step on the Body Scale to activate it The display screen turns on The device is activated Step 3 On your smartphone NantLife Application hit the Scan button Step 4 When the Body Scale icon is highlighted select it to pair Caution Your...

Page 7: ...nance Do not attempt to disassemble the measuring platform Store the unit horizontally and place it so that the buttons will not be pressed accidentally Avoid excessive impact or vibration to the unit Place the unit in an area free from direct sunlight heating equipment high humidity or extreme temperature change Never submerge in water Use alcohol or glass cleaner to clean the glass top applied t...

Page 8: ... any interference received including interference that might cause undesired operation POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet app...

Page 9: ...bject to normal wear and tear cuff batteries etc 5 Liability is excluded for direct or indirect damage caused by the device even if the damage to the device falls within the terms of the warranty 6 The above warranty extends only to the original retail purchaser 6 Unauthorized modification of the warranty card invalidates it 7 NantLife shall not be liable for loss of use or any other incidental co...

Page 10: ...de in China Distributed by NantCare LLC dba NantLife 2929 N 44th Street Phoenix Arizona 85018 Toll free phone 1 855 NANTCARE www NantLife com The manufacturer has calibrated the device for a period of two years Metrological inspection and adjustment must take place of two years Metrological inspection and adjustment is subject to a fee and can be carried out by NantLife a responsible authority or ...

Page 11: ... This device may not cause harmful interference and 2 This device must accept any interference that is received including any interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ...

Reviews: