background image

TVD Series Multifunction Scale Scale Technical Manual 

 

 

                                                                                                                                 - 8 - 

5.4 Select Weighing Units 

 Press 

 

key.It can select to kg/g/lb/oz in the weighing mode.  

 

 
 
 
 

5.5  Percent Weighing 

 
The scale can set a sample weight to be shown as 100%.  Then any other 
weights place on the scale, it will be displayed as a percentage of the original 
sample.   
 
Operation: 

1  350g weight place on the scale and follow by press the 

 key is pressed 

the display will show 100.00%.   

2  Remove the weight, and ensure display is zero  
3  Place 300g weight on the platform, display will be show 85.71 % as per the 

percentage of 350g (100%) 

4  Press 

 key to return the scale to weighing mode. 

 

  The weighing may be amended on the basis of greater numbers of 

samples, improves the accuracy of percentage large quantities.

 

 

5.6 Parts Counting 

 
In the weighing mode, it can enable scale to enter parts counting mode. 
 
Operation: 
 
1  Place the parts ( pieces ) items on the pan,  items must be placed according 

to parts options. 

2  Press the 

 key . Display shows P 10 

3  It can select the parts options by pressing 

 key . 

4  Parts options are P 10 / P 20 / P 50 / P 100 / P 200 

 

Unit mark 

Unit name 

Conversion

g

 

gram 

 

kg 

kilogram 

=1000g 

lb 

lb 

=453.59237g 

oz 

ounce 

=28.349523125g 

Summary of Contents for TVD Series

Page 1: ...TVD Multifunction Scale Version 1 01b_1 11 7 9 2020 ...

Page 2: ...5 5 Percent Weighing 8 5 6 Parts Counting 8 5 7 Tolerance checking 9 5 7 1 Limits setting for target weight 9 5 7 2 Limits setting for target quantity 10 5 7 3 Limits setting for target percentage 10 5 8 Accumulation 12 5 8 3 Memory Clear 12 5 8 4 Automatic Accumulation 13 5 9 Printing 13 5 10 Back Light Setting 13 5 11 Power Auto Off 14 5 12 Check Internal Counts 14 5 13 Gravity Setting 14 5 14 C...

Page 3: ...TVD Series Multifunction Scale Scale Technical Manual ...

Page 4: ...tion of the equipment Avoid installing the scale in direct sunlight which may cause discoloration Avoid overloading that could cause damage to the scale If the scale is not to be used for a long period of time remove battery from the battery compartment to avoid leakage Avoid stack materials on the scales when scale is not in use Avoid unsuitable tables The tables or floor must be rigid and not vi...

Page 5: ... percent weighing accumulation and units conversion Capacities from 3kg to 30kg 6lb to 60lb Rechargeable battery provide up to 70 hours of continues use with out backlight Large 24mm LCD with white LED back light display 7 embossed membrane keys 2 2 Over view 1 SST Pan 2 Weight Display 3 Key board 4 RS232 port 5 Power switch 6 AC adapter jack 7 Adjustable leveling Foot 1 2 3 4 5 6 7 ...

Page 6: ...tic pan 2 3 3 Leveling The scale is equipped with a level indicator located left side of keyboard Use the adjustable leveling feet located on the bottom of the scale until the bubble appears in the center of the indicator 3 4 Power Connection Connect the adaptor pin in to the indicator adaptor jack Adaptor jack is locating below the right side of the scale Adaptor connects into your AC power socke...

Page 7: ...at the AC power socket outlet is properly protected Right side of the display there is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be recharged If the LED is green the battery has a full charge If it is red the battery is nearly discharged 3 5 2 Battery maintenance Do not use any other type of power adaptor than the one...

Page 8: ...ter settings Limit key Set the limits for tolerance checking Right arrow key Used to move the digit to the right Scroll up menu in parameter settings Percent key Enters the percent weighing function To show weight unit weight and counts when counting parts Left arrow key Used to move the digit to the left Scroll down menu in parameter settings Sampling key To switch from parts weighing to parts co...

Page 9: ...mory N A Units key Used to select weighing units kg g N A 4 2 Display Symbols Battery indicator When it s illuminated battery should be recharge Indicate when the load above HI load below LO and with in the limits OK in check weighing mode Gross Gross Weight Net Net Weight Ο Stable indicator When it s illuminated the scale is stable Zero Zero indicator When it s illuminated the scale is in Zero po...

Page 10: ... lead to the balance exactly zero in spite of the platform not taking any strain However you can set the display of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero 5 3 Tare The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed 1 Load weight on th...

Page 11: ...0g weight on the platform display will be show 85 71 as per the percentage of 350g 100 4 Press key to return the scale to weighing mode The weighing may be amended on the basis of greater numbers of samples improves the accuracy of percentage large quantities 5 6 Parts Counting In the weighing mode it can enable scale to enter parts counting mode Operation 1 Place the parts pieces items on the pan...

Page 12: ...ithin a defined tolerance range Reaching target quantity is indicated by an audio sound if enabled in menu Note Check weighing or counting available only when weight more than 20d 5 7 1 Limits setting for target weight 1 Press key to set the check weighing function in weighing mode 2 Display will be show the indicator to set Hi Limit and the first digit will be active 000 000 kg 3 Use and keys to ...

Page 13: ... confirm 7 Scale will be confirmed the Hi Limit and display will be show the indicator to set Lo Limit and the first digit will be active 000000 pcs 8 Use and keys to shift location and press key to change the limit value and press key to confirm 9 Limits setting completed and display will return to zero Load the weight on platter the check counting control will start 5 7 3 Limits setting for targ...

Page 14: ...beep sound depends on the settings made in menu block Options Beep 0 Beep sound turned off Beep 1 Beep sound will ring out when load is within tolerance range Beep 2 Beep sound will ring out when load is beyond tolerance range When target quantity target weight target percentage is exceeds maximum tolerance limit When target quantity target weight target percentage is within tolerance range When t...

Page 15: ...is on 1 Place the items on the platform and press key when the display get stable 2 Display will be show ACC 1 and will show the total of the accumulation 3 The data will be sent to printer or PC if connected with printer or computer 4 Remove the weight from the pan for to get display zero and stable for the next accumulation 5 Scale should be get stable and zero for the next accumulation It can c...

Page 16: ...or the next operation 5 9 Printing The weighing data can be printed out by pressing keys when connected with printer To enable the printing function please as per the following settings See detail parameters 1 B9600 2 ACC ON 3 LP 50 5 10 Back Light Setting 1 Press and keys during that start up 2 Press key until display show El au 3 Press key to select the sub menu options 4 Press key to confirm El...

Page 17: ...f 5 Set to turn off five minutes later with no weight changes or key presses Of 15 Set to turn off 15 minutes later with no weight changes or key presses Of 30 Set to turn off 30 later with no weight changes or key presses 5 12 Check Internal Counts 1 Turn on the scale and press and keys during the self test Display will be show internal counts 2 Press key to return the scale to weighing mode 5 13...

Page 18: ...anual 4 Press key to confirm and back to normal weighing mode 5 14 Capacity Settings Select the jump pins as per follow to set the scale capacity TVD SERIES 3kg 6lb Short K6 and K1 6 kg 12lb Short K6 12kg 30lb Short K1 30kg 60lb No short CAL Short K4 ...

Page 19: ...lected Menu Press it can confirm which will be shown displayed Select the Menu Press or It can choose menu block one by one Press key to choose sub menu block one by one Escape from the settings Press it can escape to the normal weighing mode Active Parameter Press CAL switch to active parameter If want to change any parameter want to press CAL switch ...

Page 20: ...eigh Au on Data sending enable Au off Data sending disable B 600 B 600 Set Baud rate B 1200 B 2400 B 4800 B 9600 Tp Tp Press key to send data to TpuP receipt printer Lp 50 LAB 0 Press key to send data to DLP label printer RFT 1 Press key to send data to DEP receipt printer RFT 2 Press key to send data to DEP receipt printer Acc of Acc of Set accumulation function off Acc on Set accumulation functi...

Page 21: ...TVD Series Multifunction Scale Scale Technical Manual Spd 30 Spd 60 Of 0 Of 0 Set auto power off Of 3 Of 5 Of 15 Of 30 return Return to weighing mode ...

Page 22: ...ll weights from the platform 8 Press key when show stable indicator 9 Display will be show a calibration weight point When the display is not 000 000 press key to clear If it is necessary press and keys to select desired calibration weight 10 Press key display shows Load 11 Place the desired calibration test weight on the platform 12 Press key when show stable indicator display shows pass 13 Scale...

Page 23: ...ata bits No Parity 8 2 RS 232 9pin D type connector Pin 2 RXD Input Receiving data Pin 3 TXD Output Transmission data Pin 5 GND Signal ground 9pin D Connector Scale Computer Pin 2 Pin 3 Pin 3 Pin 2 Pin 5 Pin 5 Note if data not getting in Printer want to inter change the pin 1 and pin2 connections 8 3 Continuously output protocol HEADER1 ST STABLE US UNSTABLE HEADER2 NT NET GS GROSS WEIGHING UNIT l...

Page 24: ...munication Percentage Data Communication S T G S l b CR LF U S G S l b CR LF S T N T l b CR LF U S N T l b CR LF P C S p c s CR LF G S CR LF WEIGHT UNIT HEADER2 HEADER1 TERMINATOR WEIGHT DATA WEIGHT UNIT HEADER2 HEADER1 TERMINATOR WEIGHT DATA WEIGHT UNIT HEADER2 HEADER1 TERMINATOR WEIGHT DATA WEIGHT UNIT HEADER2 HEADER1 TERMINATOR WEIGHT DATA TERMINATOR QTY DATA QTY UNIT TERMINATOR Percentage DATA...

Page 25: ...TVD Series Multifunction Scale Scale Technical Manual 8 4 Print Formats Label Format Receipt Format 1 Receipt Format 2 ...

Page 26: ... range exceeded due to switching on Make sure platform empty Err 6 A D value out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors Err 7 Percentage Error Please check input data must be 0 5d Err19 Initialize zero error Calibration the scale ol Over range Remove the load Re calibrate fai l Calibration Error Re calibrate BaT lo Battery low Recharg...

Page 27: ...1 oz 2 g 0 002 kg 0 01 lb 0 2 oz 5 g 0 005 kg Max Divisions 6000e Weighing Units kg g lb oz Display 6 digits 0 94inch 24mm digits LCD Display with white LED back Light Platter size 9 1 x 11 8 inch 230 x 300mm Housing ABS plastic housing stainless steel platter Operation Temperature 14 F 104 F 10 C 40 C Power Input AC 100 240V output DC 12V 500mA 6V 4Ah rechargeable battery Battery life Approx 58 h...

Page 28: ...TVD Series Multifunction Scale Scale Technical Manual 10 2 DIMMENSIONS inch mm ...

Page 29: ......

Reviews: