SECTION 5: TROUBLESHOOTING GUIDE
73
EPI800 Manual.doc
EPI 800 MANUAL
2001 Vision Microsystems Inc.
FUEL FLOW TRANSDUCER TEST
1. Check that wires are correctly installed according to the harness
wiring instructions and have not broken, shorted or come loose.
2. The following measurements are made by first fabricating and
then inserting a ‘bare wire jumper’ between each respective
transducer lead to harness terminal (i.e. red to red, white to
white, black to black). If any test fails, stop and contact the
factory.
3. Measure continuity (ohms) of each wire from transducer
connector pin to appropriate harness connector pin. There should
be very low resistance if the wire is intact. If resistance is greater
that 0.7 ohms, then stop and correct connections.
4. Perform the following tests, with EPI800 power
ON
.
Meter
Common
Meter
Plus
GPH
Desired
Value
Unit under test
BLK
RED
0
4.95 to 5.05 vdc
3010019,32,35
BLK
WHT
0
0.4 to 1.1 vdc
3010019,32,35
BLK
WHT
>10
> 1.0 vac
3010019,32,35