SECTION 3: SERVICE
40
EPI800 Manual.doc
EPI 800 MANUAL
2001 Vision Microsystems Inc.
3.2
TRANSDUCER CARE AND MAINTENANCE
Never clamp down on the case of the pressure transducers with pliers
or similar tools or damage can occur.
Do not expose transducers to
any washdown fluids.
Use caution when removing and installing the air temperature probes
as they can easily be over-torqued.
Always use a new gasket when removing and re-installing the oil
temperature transducer.
3.3
DATA PROCESSOR CARE AND MAINTENANCE
The DPU requires no care or maintenance except for a battery
memory pack. This pack has a life of 10 years and tends to average
about 8 years, depending on usage and average temperature. If the
pack loses charge, then 'Initial System Set-up' is required. See this
section for details. The total tach hours can also be re-loaded.
Contact the factory for details.
The pack can be field installed by a qualified technician. Contact the
factory for details.