32
SECTION 2: OPERATION
EPI800 Manual.doc
EPI 800 MANUAL
2001 Vision Microsystems Inc.
2.14 INITIAL CHRONOMETER SET UP
You will want to set your chronometer's universal and local time
functions. This is easily done by performing the following steps:
SETTING UNIVERSAL TIME COORDINATED (UTC):
STEP 1.
With power on, place the selector switch in the 'straight up'
position (between the 'RUN' and 'STOP' positions). The
display should go blank.
STEP 2.
Turn the power off for a few seconds, then back on. After a
short period of time, the display will alternate between '
Utc ?
'
or '
Loc ?
'.
STEP 3.
First, you should set UTC time. When the display shows
'
Utc ?
', quickly move the selector switch to the 'HRS'
position. When the 'hours' value gets to the correct hour,
move the switch to the 'MIN' position. Set the 'minutes' value
a few ahead of actual time to allow you to set seconds. Move
the selector to 'SEC' and set it to your desired future time.
Move the switch to the 'STOP' position.
STEP 4.
When the preset time equals the current time, move the
selector switch to the 'straight up' position as before. The
display will read '
Utcrdy
'. Wait for this message to
disappear, then move the selector to any desired position.
(You can now check 'UTC' for the correct universal time.)