background image

Date of last revision: 2.06

ENGINEERING

GUIDES

TREADMILL.PREMIERENG.REV2

2

ENGINEERING MODE

The user must hold down 

“ELEVATION UP”

and 

“SPEED DOWN”

for 5 seconds after powering up the treadmill to

enter the engineering menus. The P6 menu appears with the software version in the message center along with the
model number. Press 

“STOP”

to exit P6. The user has 6 engineering modes to choose from. The 

“SPEED”

and 

“ELEVATION”

keys scroll through the modes, while 

“SELECT”

chooses the mode. HOLDING the 

“SELECT”

button

saves information and the 

“STOP”

button goes back to the previous screen.

Display

Engineering Mode

Configure Mode

Edits variables stored in the NOVRAM. Speed and Incline variables can be edited
in this mode.

Display Test Mode

Tests displays and keyboard

Burn In Mode

Runs continuous program

Auto-Calibration Mode

Calibrates both speed and elevation

Speed Sensor Test Mode

Tests speed sensor functionality

RS232 Test Mode

RS232 communication circuit

Exit 

Exit engineering mode

ENG1: EDIT VARIABLES MODE

The display shows the P address. To choose the P address press 

“SELECT”

.

To clear P9 total time press and hold 

“START”

for 3 seconds

To clear P10 total distance press and hold 

“START”

for 3 seconds

To clear P19, P20, and P21 time from last maintenance press and hold 

“START”

for 3 seconds

T9200/T9250/T9450 VARIABLES

Address

Description

Default Value

Min.Value

MaxValue

P0

Minimum Speed

N/A

310

600

SP1

Speed Check 2

N/A

700

1100

P1

1/2 max

N/A

1400

2100

SP2

Speed Check 4

N/A

2000

3000

P2

Max speed

N/A

3200

4500

P3

LED Brightness

3

0

9

P4

Minimum  Elevation

N/A

30

300

P5 Max 

Elevation

N/A

650

900

P6

Model and Units

N/A

N/A

N/A

P7

Max Time

99

15

99

P8

Default Weight

150

80

400

P9

Accumulated Time

N/A

N/A

N/A

P10

Accumulated Distance

N/A

N/A

N/A

P11

Belt Thickness (depends on the model)

13

44

P12

Roller Diameter

60

60

60

P13

Elevation motor

1

P14

Pause Time

5:00

:20

10:00

P15

Default Time

30

1

99

P16

Default Age

40

5

120

P17

Elevation Errors (turn on/ off)

1

N/A

N/A

Premier Upper Board: Engineering Guide 

Summary of Contents for PREMIER UPPER BOARD

Page 1: ...ision 2 06 ENGINEERING GUIDES TREADMILL PREMIERENG REV2 1 S T A N D A R D C O N S O L E F O R T9200 PREMIER T9500 PREMIER T9600 PREMIER T9250 PREMIER T9450 PREMIER T9700S T9700HRT PREMIER UPPER BOARD ENGINEERING GUIDE ...

Page 2: ...ity RS232 Test Mode RS232 communication circuit Exit Exit engineering mode ENG1 EDIT VARIABLES MODE The display shows the P address To choose the P address press SELECT To clear P9 total time press and hold START for 3 seconds To clear P10 total distance press and hold START for 3 seconds To clear P19 P20 and P21 time from last maintenance press and hold START for 3 seconds T9200 T9250 T9450 VARIA...

Page 3: ...d Check 4 N A 3000 4200 P2 Max speed N A 3900 5200 P3 LED Brightness 3 0 9 P4 Minimum Elevation 250 30 300 P5 Max Elevation 850 650 900 P6 Model and Units N A N A N A P7 Max Time 99 15 99 P8 Default Weight 150 80 400 P9 Accumulated Time N A N A N A P10 Accumulated Distance N A N A N A P11 Belt Thickness depends on the model 13 44 P12 Roller Diameter 60 60 60 P13 Elevation motor 1 N A N A P14 Pause...

Page 4: ...ss the seven segment display and a character in the message center and a column in the dot matrix move from Left to Right ELEVATION DOWN Shifts 8 across the seven segment display and a character in the message center and column in the dot matrix moves from Right to Left START Turns on the Function LEDs one at a time Continue to press START to test each LED ELEVATION 1 9 Displays Elevation number i...

Page 5: ...tomatically backs off to set 0 elevation The software will then look where the elevation stalls for the highest point the treadmill elevation will go The software will automatically back off and set the maximum elevation 12 or 15 depending on the treadmill model Meanwhile the belt is being driven while the speed is being monitored As it reaches the minimum speed 1 1 2 max speed 2 and max speed the...

Page 6: ...the magnet reconnects to the console the board resets Any activity or run time information prior to the reconnection will be lost Elevation Range Elevation Stall Elevation Lost Over speed No Speed Feedback E4 E4 E6 E7 E9 Current elevation position is outside zero and max elevation values Current elevation position has not reached target incline Current elevation position is outside zero and max el...

Page 7: ... changing units does affect the stored value of weight and clears any stored user programs Changing units may also require you to perform auto calibration P7 MAX TIME P7 represents maximum time You can modify the time by using either set of arrow keys Press and hold SELECT to enter P8 DEFAULT WEIGHT P8 represents default weight Weight appears in the alphanumeric window To modify weight press the S...

Page 8: ...ECT to save prior to exiting To exit press STOP P21 CHECK MOTOR BRUSHES MESSAGE T9700S T9700HRT ONLY P21 represents whether the service message for check motor brushes has been enabled If enabled a 1 appears in the alphanumeric display Otherwise a 0 appears if disabled To disable the message you must press one of the arrow keys so that a 0 appears in the right window Then press SELECT to save prio...

Reviews: