ERROR MESSAGES

Three types of errors can occur; speed, elevation, and EEPROM software error. All three use the same display to 
indicate the error, with the error number appearing in the main window. An elevation error shuts down the treadmill
and disables normal operation. A speed sensor error also shuts down the treadmill. The user, however, can enter 
engineering mode after an error announcement.

Premier Upper Board: Engineering Guide 

ERROR

DISPLAY DESCRIPTION

SOLUTION

SAFETY SWITCH

If the safety magnet disconnects from the console, the treadmill shuts down if in run mode. The treadmill displays 

““--------““    

in

the main window. This is a safety precaution to warn the user that power is still being applied to the board. This safety
switch condition occurs in any mode, including engineering modes.

When the magnet reconnects to the console, the board resets. Any activity or run time information prior to the reconnection
will be lost.

Elevation

Range

Elevation

Stall

Elevation

Lost

Over speed

No Speed

Feedback

E4

E4

E6

E7

E9

Current elevation position is outside
zero and max elevation values 

Current elevation position has not
reached target incline 

Current elevation position is outside
zero and max elevation values, due
to elevation signal getting lost.  

Speed of the belt surpasses the 
calibrated max speed by 1.0 mph or
km/h as measured by the speed sensor

No speed is detected during 
Auto-Calibration

Enter ENG 1 and manually position elevation within
the min and max values. If not possible, recalibrate
min and max elevation

Check for bad cable connection. Check for connection
between motor controller and elevation motor. Try to
reboot system

Check for bad cable connection. Check for connection
between motor controller and elevation motor. Check
for bad elevation motor

Cycle power to clear error. Check speed sensor and
magnets

Check speed sensor and magnets

Summary of Contents for PREMIER UPPER BOARD

Page 1: ...ision 2 06 ENGINEERING GUIDES TREADMILL PREMIERENG REV2 1 S T A N D A R D C O N S O L E F O R T9200 PREMIER T9500 PREMIER T9600 PREMIER T9250 PREMIER T9450 PREMIER T9700S T9700HRT PREMIER UPPER BOARD ENGINEERING GUIDE ...

Page 2: ...ity RS232 Test Mode RS232 communication circuit Exit Exit engineering mode ENG1 EDIT VARIABLES MODE The display shows the P address To choose the P address press SELECT To clear P9 total time press and hold START for 3 seconds To clear P10 total distance press and hold START for 3 seconds To clear P19 P20 and P21 time from last maintenance press and hold START for 3 seconds T9200 T9250 T9450 VARIA...

Page 3: ...d Check 4 N A 3000 4200 P2 Max speed N A 3900 5200 P3 LED Brightness 3 0 9 P4 Minimum Elevation 250 30 300 P5 Max Elevation 850 650 900 P6 Model and Units N A N A N A P7 Max Time 99 15 99 P8 Default Weight 150 80 400 P9 Accumulated Time N A N A N A P10 Accumulated Distance N A N A N A P11 Belt Thickness depends on the model 13 44 P12 Roller Diameter 60 60 60 P13 Elevation motor 1 N A N A P14 Pause...

Page 4: ...ss the seven segment display and a character in the message center and a column in the dot matrix move from Left to Right ELEVATION DOWN Shifts 8 across the seven segment display and a character in the message center and column in the dot matrix moves from Right to Left START Turns on the Function LEDs one at a time Continue to press START to test each LED ELEVATION 1 9 Displays Elevation number i...

Page 5: ...tomatically backs off to set 0 elevation The software will then look where the elevation stalls for the highest point the treadmill elevation will go The software will automatically back off and set the maximum elevation 12 or 15 depending on the treadmill model Meanwhile the belt is being driven while the speed is being monitored As it reaches the minimum speed 1 1 2 max speed 2 and max speed the...

Page 6: ...the magnet reconnects to the console the board resets Any activity or run time information prior to the reconnection will be lost Elevation Range Elevation Stall Elevation Lost Over speed No Speed Feedback E4 E4 E6 E7 E9 Current elevation position is outside zero and max elevation values Current elevation position has not reached target incline Current elevation position is outside zero and max el...

Page 7: ... changing units does affect the stored value of weight and clears any stored user programs Changing units may also require you to perform auto calibration P7 MAX TIME P7 represents maximum time You can modify the time by using either set of arrow keys Press and hold SELECT to enter P8 DEFAULT WEIGHT P8 represents default weight Weight appears in the alphanumeric window To modify weight press the S...

Page 8: ...ECT to save prior to exiting To exit press STOP P21 CHECK MOTOR BRUSHES MESSAGE T9700S T9700HRT ONLY P21 represents whether the service message for check motor brushes has been enabled If enabled a 1 appears in the alphanumeric display Otherwise a 0 appears if disabled To disable the message you must press one of the arrow keys so that a 0 appears in the right window Then press SELECT to save prio...

Reviews: