General System Parameters
SYSTEM > 1/2CAL > PAR Menu
VT300 Technical Manual, Rev. A4
39
Doc
#
TM-VT300-EN
5.2 SYSTEM
>
1/2CAL > PAR Menu
#
Parameter
Description
Values
00 2SCL
ENABLE
(only appears
in
1CAL
menu)
Scale 2 enable.
Activates the second scale input. This
option only appears in the 1CAL menu. If set to NO,
parameters in the
2CAL
menu are ignored.
YES, NO
01 S1+S2
ENABLE
(only appears
in
2CAL
menu)
*
Sum of two scales.
YES specifies that the
key should toggle between scale
1 weight, scale 2 weight and the sum of both scales.
NO specifies that the
key should only toggle between
scale 1 weight and scale 2 weight.
YES, NO
02 DISP.DIGITS
Number of display digits
. 4,
5,
6
03 DEC.POINT
*
Number of digits after decimal point
. Defines the
position of the decimal point.
0-5
04 SCALE
DIV.
*
Display resolution
.
1, 2, 5, 10, 20, 50,
100, 200
05 WEIG.RANGE
Two most significant digits of full load
. 00-99
06 DIG.
FILTER
Digital filter
. If x is entered, filter averages 2
x
samples. 0
is considered low, 3 is normal and 5 is high.
0-5
07 CONV.
RATE
*
Number of conversions per second
. If there are two
scales connected, the sum of their conversion rates
(6P+6P) must be less than 70. Otherwise the unit sets
CONV.RATE=14 for each scale.
3, 7, 14, 28, 57, 70
08 MOTION
SAMPLES
No-motion samples.
Number of samples for no-motion
detection. 1 is considered low; 7 is considered high.
1-7
09 AUTO
Z
TRACK
Auto-zero tracking
, with a maximum of 0.5 display
divisions per second.
YES, NO
10 INIT
ZERO
Auto-zero at power up
. If enabled, sets the instrument
to zero on power-up. It the starting weight is outside the
zero range,
E.15
is displayed (see chapter
10).
YES, NO
11 DUAL
FILTER
Dual digital filter
(anti-flicker). The digital filter increases
automatically when the scale is not in motion.
YES, NO
12 A/D
AUTO
CON
Automatic clearing of A/D converter errors
.
NO specifies that, when the A/D converter is enabled,
errors are automatically cleared when the cause is no
longer present.
YES specifies that A/D converter errors should remain on
the display until the operator presses
ESC
.
YES, NO
13 BATTERY
Battery conversion.
Enables battery conversion, for
battery-powered models.
YES, NO