Outputs and Digital Input
Setting Thresholds for Digital Setpoints
VT300 Technical Manual, Rev. A4
64
Doc # TM-VT300-EN
7.3.1
Setpoint Options
To edit setpoint options:
1. Press
MENU
and navigate to
SETUP
>
SET
>
SETP
.
The following dialog’s first four parameters (SETP 1.1, 1.2, 2.3 and 2.4) can be
set in several combinations. See ‘Setpoint On/Off Combinations’ below for the
implication of each possible combination.
2. The display shows
SETP 1.1 ON
/
OFF
. Set this parameter to
ON
or
OFF
(refer to the
table below).
3. The display shows
SETP 1.2 ON
/
OFF
. Set this parameter to
ON
or
OFF
(refer to the
table below).
4. The display shows
SETP 2.3 ON
/
OFF
. Set this parameter to
ON
or
OFF
(refer to the
table below).
5. The display shows
SETP 2.4 ON
/
OFF
. Set this parameter to
ON
or
OFF
(refer to the
table below).
6. The display shows
SETUP GROSS=NO
/
YES
. Set this parameter to:
NO
, to specify that setpoints should be activated by net weight.
YES
, to specify that setpoints should be activated by gross weight.
Setpoint On/Off Combinations
Parameters Used
for
Combinations
SETP 1.1,
SETP 1.2
Setpoint 1 output.
1.1=0 and 1.2=0: normal
1.1=1 and 1.2=0: no motion
1.1=0 and 1.2=1: error
SETP 2.3,
SETP 2.4
Setpoint 2 output.
2.3=0 and 2.4=0: normal
2.3=1 and 2.4=0: zero
2.3=0 and 2.4=1: net
5.6
Net / gross
for both setpoints.
0=net
1=gross
5.7
Normally open / closed for both
setpoints.
0=normally open
1=normally closed