14 / 36
Remove the 4 screws (21).
Remove dosing head (20).
Remove seals (18 + 19). During assembly, grease seals with suitable lubricant
(e.g. OKS 469). Do not use silicone.
Pull out sliding bushing (16) and mixer shaft (15).
Remove the 4 screws (27).
Remove mounting plate (28).
Separate the dispenser halves.
Fig. 3
15
16
S12
34
5
20
21
18
19
Fig. 4
27
28
S12
34
5
S12345