16 / 36
4.1.3
Reassembling the dispenser
For reassembly, the work steps outlined in Section 4.1.1 (page 13) are carried out in reverse
order.
When doing this, observe the following
Only tighten up the screw (7) very slightly.
Assemble the halves of the dispenser.
Mount dosing head (20) with screws (21).
Tighten screws (7) using the holes in the dosing head (20).
NOTE
Do not exceed a tightening torque of 0.35 Nm when mounting the screws.
Fig. 7
6B
7
S12
34
5
21
21
7
S12
34
5
S123
45
20
Fig. 8