Dosing system eco-CONTROL EC200-K
Operation and maintenance instructions
Copyright ©
Version 1.8
5.9.8
Analogue Input
Description:
The flow rate (ml/min) of the connected pump(s) is controlled
proportional to the applied analogue signal (V or mA).
This function is only active in the
Start / Stop program
.
Note:
Whatever the setting of the flow rate (ml/min) in the
Start / Stop program
, the
maximum flow rate of the pump (see table above) must always be assumed. This
setting does not affect the return.
Switching the analogue input on / off
• Press the
PRG
key,
system selection menu
, display 2
appears.
• Select and confirm
Administration
, the
Administration
menu
, display 25 appears.
Displ
ay 2
• Select
Analogue Input
, display 43 appears.
The current setting is shown in the status bar.
Display 25
• Select the desired setting and press
Navi wheel
, the status
bar displays
Press OK to accept.
• Select the
OK
button and confirm, the setting is activated.
Displ
ay 43
Note:
If one of the two analogue inputs is active, this will be
indicated in plain text in the display of the
Start / Stop
Program
(display 44) instead of the dynamic flow rate
display.
Display 44
Technical connection data on the system connector (15)
Pin
Analogue
signal
Input resistance / resolution
Pump
ml/min
A1
0-10V
Ri = k 20 k
Ω
/ 10 bit
ecoPEN300
echPEN450
ecoPEN600
0 - 1,48
0 - 6
0 -16
A2
04-20mA
Ri = 100
Ω
/ 10Bit
Maximum input v5V
ecoPEN300
echPEN450
ecoPEN600
0 - 1,48
0 - 6
0 -16
GND GND Analog
Start/stop
Time program
Calibration auto
Calibration manuel
Teach in function
Administration
Quantity program
10 47h
Fr 18.03.11
Service
Esc OK
Change program
Tolerance of pressure
Password protection
Analog input
Adjust time
Select program
Esc
Analog input
Analog inactive
Off
OK
A1
A2
Start/stop
Esc
Suckback
Flow rate
A1 aktiv
0.000
ml
O
Start/ stop
Summary of Contents for Preeflow eco-CONTROL EC200-K
Page 2: ...Item No 20202 Print 20 1 12 ...
Page 36: ......