Dosing system eco-CONTROL EC200-K
Operation and maintenance instructions
Version 1.8
Copyright ©
5.9
Settings
5.9.1
Dosing amount
General on determining the dosing amount.
Note:
If a value that differs from 100% is set in the
Calibration manual
menu
), this affects the results of the dosing.
There are two options to choose from:
A) Determination via calculation
It is easiest to determine the smallest dosing quantities by weight. We recommend that
you first set the material density.
Dose the required amount with the
start / stop program
and weigh it out. Now input in the
quantity program
the quantity in
g
.
B) Teach in, empirical determination
Use the
Teach in
function if you wish to determine the required amount by means of doing
(for example, filling a void). The Dosing system saves the required amount.
• Press the
PRG
key,
system selection menu
, display 2
appears.
• Select and confirm
Calibration manual
, the
Calibration
manual
menu, display 40 appears.
Displa
y 2
• Confirm the flow rate and set the desired value with the
NAVI wheel
• Press the
OK
button,
system selection menu
, display 2
appears.
Displa
y 40
Setting the dosing amount as a value
1. Press the
Quantity program
shortcut key, display 3
appears.
2. Ensure that the required quantity unit* has been
selected in the
Quantity
display area.
3. Set and confirm the dosing amount.
Displa
y 3
* If the saved density value corresponds to the value 1.000 g/cm³ (default value), the
input dialog for the material density appears when you select
g
Start/stop
Time program
Calibration auto
Calibration manuel
Teach in function
Administration
Quantity program
10 47h
Fr 18.03.11
Service
Esc OK
Accept with OK
Esc
Calibration manuel
OK
degree of dosing qty
Adjustment range 90% ..110%
100.0 %
100.0 %
100.0
Quantity program
Esc
Suckback
Flow rate
Volume
0%
100%
ml/min
00.100
03.000
00.000
ml
ml