2. ADJUSTING BLADES AND BLADE HOLDERS

Blade holders are regulated before leaving the factory 
and do not require readjustment when changing the 
blade. Nonetheless, if for any reason they have to be 
adjusted, do so as follows:
Using the knob A and the wheel B (Fig. 1 and 6), 
align and block the surface of the base N (Fig. 5) with 
the cutting edge of the blade in the best condition, 
which will used as a reference. 
In the event that blade holders or blades become 
lost or worn out, leave a distance of 1 mm between 
the edge of the blade and the diameter of the cut-
terblock P (Fig. 6).
Loosen slightly in the clockwise direction the two 
screws G (Fig. 2) of the blade blade holder J, which 
should be adjusted using the service key. 
Place a rule over the base and adjust the screws R (Fig. 
5) in order to withdraw or retract the blade holder 
with the fitted blade until the entire length of its 
cutting edge is flush and parallel with the base N. 
Check that the side of the blade H does not protrude 
out from its holder J, and that the blade holder is 
lined up with the side of the cutterblock P (Fig. 3), 
and tighten the two screws G (Fig. 2) in the counter-
clockwise direction with the service key. 

Ensure that the 4 screws G (Fig. 2) are 

well-tightened before resuming work 

with the edge lipping planer after 

making any blade changes or blade 

holder adjustments.

When replacing the cutterblock, use only original 
Wegoma by Virutex components.

11. CHANGE OF THE DRIVING BELT

Disconnect the equipment from the ma-

ins before carrying out this operation.

 
Remove the protective cover S (Fig. 7), unscrewing 
the screw T that fastens it. 
Turn the pulleys whilst at the same time pulling worn 
belt V for extraction.
Carefully clean the toothed pulleys before replacing 
the belt with a new genuine Wegoma by Virutex belt.
Mount the new toothed belt V, making sure that its 
teeth are properly intermeshed with those of the 
cutterblock pulley and those of the driving wheel. 
Place again protection S (Fig. 7).

12. MAINTENANCE OF 

BRUSHES AND COLLECTOR

Always remove the plug from the mains 

socket before carrying out any work 

on the machine.

It is important that brushes be changed when they 
have a minimum length of 5 mm. Unscrew the brush 
cap Y (Fig. 8) and remove the brushes from the guides. 
Replace brushes with genuine Wegoma by Virutex 
ones and check to ensure that they slide smoothly 
in their guides.
After screwing the brush cap back on, it is recommen-
ded to leave the machine running for 15 minutes in 
order to ensure that brushes adapt properly. 

Should you detect burns or ribbing on 

the collector, have it repaired at a We-

goma by Virutex technical service outlet.

 

13. NOISE AND VIBRATION LEVEL

The noise and vibration levels of this device have 
been measured in accordance with European stan-
dard EN60745-2-14 and EN 60745-1 and serve as 
a basis for comparison with other machines with 
similar applications.
The indicated vibration level has been determined 
for the device’s main applications and may be used 
as an initial value for evaluating the risk presented 
by exposure to vibrations. However, vibrations 
may reach levels that are quite different from the 
declared value under other application conditions, 
with other tools or with insufficient maintenance 
of the electrical device or its accessories, reaching a 
much higher value as a result of the work cycle or 
the manner in which the electrical device is used.
Therefore, it is necessary to establish safety measures 
to protect the user from the effects of vibrations, 
such as maintaining both the device and its tools 
in perfect condition and organising the duration 
of work cycles (such as operating times when the 
machine is subjected to loads, and operating times 
when working with no-load, in effect, not in use, as 
reducing the latter may have a considerable effect 
upon the overall exposure value).

14. WARRANTY

All Wegoma by Virutex power tools are guaranteed 
for 12 months from the date of purchase, excluding 

Summary of Contents for WEGOMA AP98N

Page 1: ...Edge lipping planer Cepillo enrasador Rabot araser Pialletto per bordi Plaina de cantos AP98N GEBRAUCHSANWEISUNG OPERATING INSTRUCTIONS MANUAL DE INSTRUCCIONES MODE D EMPLOI MANUALE D ISTRUZIONI MANUA...

Page 2: ...MODE D EMPLOI MANUALE D ISTRUZIONI MANUAL DE INSTRU ES Seite p gina page pagina DEUTSCH Umleimerhobel AP98N 4 ENGLISH AP98N Edge lipping planer 7 ESPA OL Cepillo enrasador AP98N 10 FRAN AIS Rabot ara...

Page 3: ...3 Abb Fig 3 Abb Fig 4 Abb Fig 5 Abb Fig 6 Abb Fig 8 Abb Fig 7...

Page 4: ...h rschutz zu tragen 11 Es wird empfohlen die Maschine w hrend des Betriebs an eine Absaugung anzuschlie en 12 VerwendenSiedieMaschineaufkeinenFall wenn der Schutz am Messerhalter nicht angebracht ist...

Page 5: ...d AS382L oderirgendeinandererIndustriesaugerangeschlossen werden DerexterneStaubsauganschlussF Abb 1 darf nie am Ger t montiert sein wenn kein Sauger verwendet wird da die abgehobelten Sp ne sonst nic...

Page 6: ...ne minimale L nge von 5 mm haben Den Stopfen Y Abb 8 abschrauben und die Kohle aus der F hrung nehmen Die B rsten durch Original Wegoma by Virutex Koh leb rsten ersetzen und berpr fen ob sie leicht in...

Page 7: ...ggleswhenworkingwiththismachine 3 Use anti dust protection mask 4 Keepyourhandsawayfromthecuttingarea Always guide the planer firmly with both hands 5 Avoid cutting nails Check the work surface before...

Page 8: ...reaching the end of the thread Spin thewheelBtoraiseorlowerthecutterblock adjusting it to the necessary flushing height After setting the flushing height screw on the knob A in the clockwise direction...

Page 9: ...with those of the cutterblock pulley and those of the driving wheel Place again protection S Fig 7 12 MAINTENANCE OF BRUSHES AND COLLECTOR Alwaysremovetheplugfromthemains socket before carrying out a...

Page 10: ...chapa de caracter sticas 2 Use las gafas de seguridad para trabajar con esta m quina 3 Usar mascarilla de protecci n antipolvo 4 Mantenga las manos alejadas del rea de corte y sujete siempre la m quin...

Page 11: ...ue cuandopordesgastedelfreno observequeeltiempo de parada es superior se dirija a un Servicio T cnico Wegoma by Virutex para proceder a su sustituci n 7 REGULACIONES DE CORTE ALTURA DE ENRASADO Desenr...

Page 12: ...ecambiosenelportacuchillas utilizarexclusiva mente componentes originales Wegoma by Virutex 11 CAMBIODELACORREADETRANSMISI N Desconectar la m quina de la red el ctrica antes de efectuar cualquier oper...

Page 13: ...mo y d nde pueden llevarlo para que sea sometido a un reciclaje ecol gico y seguro WegomabyVirutex sereservaelderechodemodificar sus productos sin previo aviso F R A N A I S RABOT ARASER AP98N 1 INSTR...

Page 14: ...d un interrupteur de s curit enclenchement invers qui emp che les mises en marche accidentelles de la machine Pour mettre en marche la machine appuyer sur la s curit duboutonZ Fig 1 etsimultan mentapp...

Page 15: ...uteau en meilleur tat que l on prendra comme r f rence Encasdeperteouded t riorationtotaledessupports de couteaux ou des couteaux laisser une distance de 1 mm entre le tranchant du couteau et le diam...

Page 16: ...e d achat en tant exclus toutes manipulations oudommagescaus spardesmaniementsinad quats ou par l usure naturelle de la machine Pour toute r paration s adresser au service officiel d assistance techni...

Page 17: ...pirazione esterna da 2 25 m 5 DESCRIZIONE GENERALE E APPLICAZIONI Il pialletto per bordi AP98N dotato di Lame reversibili di MD Pomello regolatore della passata di taglio che permette un altezza di pa...

Page 18: ...e supporto J non fuoriescano lateralmente dal portacoltelli P SerrareenergicamenteleduevitiG Fig 2 ruotandole in senso antiorario con la chiave in dotazione Se fosse necessario sostituire i supporti c...

Page 19: ...ltri strumenti di lavoro o in caso dimanutenzioneinsufficientedell apparatoelettrico e dei suoi strumenti e pu aumentare notevolmente come conseguenza del ciclo di lavoro e del modo d uso dell apparat...

Page 20: ...12 Nunca usar a m quina tendo a protec o do portanavalhas desmontada 2 CARACTERISTICAS Pot nciaabsorvida 1 300W Motoruniversal 50 60Hz Velocidadeenvazio 10 000 min 1 Cortesporminuto 20 000 Larguradeco...

Page 21: ...as cortadas 10 SUBSTITUI O E REGULA O DAS NAVALHAS Antes de realizar esta opera o h que desligar a m quina da corrente el ctrica 1 SUBSTITUI O DAS NAVALHAS E DOS SUPORTES DAS NAVALHAS Para substituir...

Page 22: ...trica importante substituir as escovas quando estas tiverem um comprimento m nimo de 5 mm Desaperte o tamp o Y Fig 8 e extraia a escova da guia Substitua as escovas por outras originais da Wegoma by V...

Page 23: ...nte Respeite os regulamentos em vigor no seu pa s Aplic vel na Uni o Europeia e nos pa ses europeus com sistemas de recolha seletiva de res duos A presen a deste s mbolo no produto ou no material info...

Page 24: ...5396693 022021 WEGOMA VIRUTEX CONNECTION GmbH Auf der Hub 34 76307 Karlsbad Ittersbach www wegoma virutex de...

Reviews: