background image

VirtuFit  Row 1000 Rowing Machine

10

EN

FILL AND EMPTY THE TANK

WATER LEVEL

WATER TANK

 • Remove the Fill Plug (49) from the Upper Tank Cover.

 • To fill tank with water, refer to Fig. A. Insert the Funnel (92) into the tank, then use a cup or the  

  Pumping siphon (91) and a bucket to fill the tank. Use the water level gauge on the side of the tank  
  to measure desired water level in the tank.

 • To empty the tank, refer to Fig. B. Place a bucket next to the rower, and use the Pumping siphon (91)  

  to pump out the water from the tank into the bucket.

 • Insert the Fill Plug (49) into the Upper Tank Cover. Wipe excess water off of the frame.

NOTE!

 • Fill the tank only with tap water. Add 1 water-purification tablet (1 packet is included.). Never use  

  pool chlorine or chlorine bleach. This will damage the tank and void the warranty.

 • Add a water purification tablet every 6 months or as needed. If water remains cloudy, replace the  

  water in the tank.

 • Water from the tank is not suitable for consumption. Dispose the water after pumping it out from  

  the tank.

 • See Fig. A. The water level gauge is on the side of the tank.  

  The maximum fill is the top bar. Never fill it over this limit.  
  Filling the tank over this limit will void the warranty.

 • The resistance depends on the water level in the tank. Water  

  level 1 is the lowest resistance. Level 6 is a higher resistance.

ENG

9

VirtuFit Water Resistance Row 1000

HOW TO FILL AND EMPTY THE TANK

1.  Remove the Fill Plug (49) from the Upper Tank Cover; 

2.  To fill tank with water, refer to Fig. A. Insert the Funnel (92) into the tank, then use a cup or the Pumping  

siphon (91) and a bucket to fill the tank. Use the water level gauge on the side of the tank to measure 
desired water level in the tank.  

3.  To empty the tank, refer to Fig. B. Place a bucket next to the rower, and use the Pumping siphon (91) to 

pump out the water from the tank into the bucket.  

4.  Insert the Fill Plug (49) into the Upper Tank Cover. Wipe excess water off of the frame. 

NOTE:

 

– Fill the tank only with tap water. Add 1 water-purification tablet (1 packet is included.). Never use pool 

chlorine or chlorine bleach. This will damage the tank and void the warranty.  

 

– Add a water purification tablet every 6 months or as needed. If water remains cloudy, replace the water 

in the tank.  

 

– Water from the tank is not suitable for consumption. Dispose the water after pumping it out from the 

tank. 

 

– See Fig. A. The water level gauge is on the side of the tank. The maximum fill is the top bar. Never fill it 

over this limit. Filling the tank over this limit will void the warranty.  

 

– The resistance depends on the water level in the tank. Water level 1 is the lowest resistance. Level 6 is 

a higher resistance. 

WATER LEVEL

ENG

9

VirtuFit Water Resistance Row 1000

HOW TO FILL AND EMPTY THE TANK

1.  Remove the Fill Plug (49) from the Upper Tank Cover; 

2.  To fill tank with water, refer to Fig. A. Insert the Funnel (92) into the tank, then use a cup or the Pumping  

siphon (91) and a bucket to fill the tank. Use the water level gauge on the side of the tank to measure 
desired water level in the tank.  

3.  To empty the tank, refer to Fig. B. Place a bucket next to the rower, and use the Pumping siphon (91) to 

pump out the water from the tank into the bucket.  

4.  Insert the Fill Plug (49) into the Upper Tank Cover. Wipe excess water off of the frame. 

NOTE:

 

– Fill the tank only with tap water. Add 1 water-purification tablet (1 packet is included.). Never use pool 

chlorine or chlorine bleach. This will damage the tank and void the warranty.  

 

– Add a water purification tablet every 6 months or as needed. If water remains cloudy, replace the water 

in the tank.  

 

– Water from the tank is not suitable for consumption. Dispose the water after pumping it out from the 

tank. 

 

– See Fig. A. The water level gauge is on the side of the tank. The maximum fill is the top bar. Never fill it 

over this limit. Filling the tank over this limit will void the warranty.  

 

– The resistance depends on the water level in the tank. Water level 1 is the lowest resistance. Level 6 is 

a higher resistance. 

WATER LEVEL

Summary of Contents for Row 1000

Page 1: ...Row 1000 Rowing Machine User manual EN Water Resistance Row 1000 User Manual...

Page 2: ...NSTRUCTIONS WATER TANK WATER TANK ADJUSTMENT GUIDE ADJUSTMENT GUIDE MOVING AND STORE MOVING AND STORE MAINTENANCE MAINTENANCE TROUBLE SHOOTING TROUBLE SHOOTING CONTROL PANEL CONTROL PANEL EXPLODED DRA...

Page 3: ...irregular heartbeat extreme shortness of breath lightheadedness dizziness or feelings of nausea If you do experience any of these conditions you should consult your doctor before continuing with your...

Page 4: ...or seek assistance if necessary Please keep the space at least 1 to 2 meter at the end of base frame to escape any accidents Place the device on a clean and flat surface Do not place the device on a t...

Page 5: ...e below parts in the carton ENG 4 VirtuFit Water Resistance Row 1000 CHECKLIST No 1 No 38 No 51 No 3 L R No 2 No Description QTY 1 Main frame 1 2 Rear Stabilizer 1 3 L R Slide rail 2 38 Seat 1 51 Comp...

Page 6: ...Machine 6 EN CHECKLIST TOOLKIT ENG 5 VirtuFit Water Resistance Row 1000 CHECKLIST TOOL KIT 57 M8 45 6 pcs 61 M8 75 4 pcs 71 M8 8 pcs 89 S5 1 pc 90 S13 17 1 pc 95 M8 6 pcs 94 M8 6 pcs 68 OD20 ID8 5 1...

Page 7: ...e picture Install the slide rail 3 L R into the seat Attach the Rear Stabilizer 2 to the Slide Rail 3 tighten with 4 Washers 68 and 4 screws 57 Missing parts If you think you are missing certain parts...

Page 8: ...n with 8 Arc Washers 71 4 screws 61 4 screws 61 4 spring washers 95 and 4 cap nut 94 4 washers 68 4 screws 57 2 spring washers 95 and 2 cap nut 94 ASSEMBLY INSTRUCTIONS Attach the Slide Rail 3 to the...

Page 9: ...4 Washers 68 and 4 screws 58 If the seat makes noise the wheels under the seat should be slightly greased with the supplied supplied silicone oil Connect the connection wire 85 to the sensor wire 84...

Page 10: ...ank into the bucket 4 Insert the Fill Plug 49 into the Upper Tank Cover Wipe excess NOTE Fill the tank only with tap water Add 1 water purification tabl chlorine or chlorine bleach This will damage th...

Page 11: ...G THE BALANCE The pedal strap is adjustable and can be personalized to fit the user s foot size To adjust the pedal strap remove theVelcro end of the strap from the mesh side by pulling it upward then...

Page 12: ...the transportation wheels on the front stand touch the ground With the wheels on ground you can transport the rower to the desired location with ease NOTE The seat moves When not in use you can save s...

Page 13: ...MI ANNUAL MAINTENANCE DAILY MAINTENANCE Clean and remove sweat after each use Do not use aggressive cleaning agents and ensure that the device remains free of moisture Check that the rail and the whee...

Page 14: ...ded period of time in order to avoid hazards through leaking batteries 2 Do not recharge batteries nor dissemble or throw then into fire Danger of explosion 3 Pay attention to the polarity and Always...

Page 15: ...lay Display shows no values If the display does not show any values you can try to check the sensor cables and the cables in the back of the display If this still does not work you can move the sensor...

Page 16: ...ection 2 Press to return to standby mode during stop 3 Hold it for 2 seconds and the computer will reset START STOP To start or stop the selected training program ENTER 1 Press to confirm the selected...

Page 17: ...es from start to finish CALORIES Counts the total calories from the beginning to the end of rowing PULSE PUL Displays the heart rate during exercise DRAG FORCE Displays the current drag speed WATT Dis...

Page 18: ...ctions of the training mode from 2000m 5000m 10000m 30 00 500m 1 00 Then press START STOP to start training The preset function value will count down other function value will count up Press RESET to...

Page 19: ...rest for 30 seconds V1 00 1 00R 7 train for 1 minute rest for 1 minute repeat 7 times V2000m 3 00R 4 train 2000 meters rest 3 minutes repeat 4 times V1 40 20R 1 minute workout in 40 seconds rest 20 s...

Page 20: ...ton All function displays stop TIME starts to count down from 06 00 to 00 00 Your condition is measured The screen will display your heart rate status with F1 F2 to F6 F1 is excellent F6 is bad The us...

Page 21: ...VirtuFit Row 1000 Rowing Machine 21 EN 22 VirtuFit Water Resistance Row 1000 NL TECHNISCHE TEKENING EXPLODED DRAWING...

Page 22: ...rrying wheel 2 24 Adjustable end cap 2 25 Oval plug 2 26 Upper tank 1 27 Lower tank 1 28 Decorate cover 1 29 Handlebar seat 1 30 Top pedal 2 DESCRIPTION QTY 31 Under pedal 2 32 Beang seat 1 33 Mesh be...

Page 23: ...on locknut M10 7 75 Nylon locknut M8 10 76 Nylon locknut M6 4 77 Nylon locknut M5 8 78 O shape ring M4 1 79 Nylon locknut M3 12 80 Cross screw M3 20 12 81 Washer OD7 ID3 2 1 0 24 82 Screw M10 50 1 83...

Page 24: ...es that raise your heart rate and warm the working muscles Activities may include brisk walking jogging jumping jacks jump rope and running in place Stretching while your muscles are warm after a prop...

Page 25: ...For questions or missing parts please contact your dealer...