14: Configuring ignition sense
_______________________________________________________________________________________________________
_____________________________________________________________________________________________________
© Virtual Access 2017
GW3300 Series User Manual
Issue: 1.7
Page 113 of 372
14.4
Ignition sense diagnositcs
14.4.1
Monitoring Vapowermond status using the command line interface
To view status information about the current ignition sense state enter:
root@VA_router:~# cat /sys/class/gpio/gpio29/value
1
1 for ignition on;0 for ignition off