Operation

13

Section 5

Operation

5.1 Controller

Figure 3 Controller

Buttons and Display

Feature

Description

Function

A

Lamp timer 

display

Counts down from 365 days to show time for annual lamp replacement.

B

Lamp timer reset

After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365.

C

Mute

Press to silence audible alarm.

When the alarm is due to the lamp's age, the mute button will silence the audible alarm for 7 days; 

this may be repeated up to a maximum of 4 times. After that, the button will silence for only 24 hours.

When the alarm is due to any other issue, the mute button will silence the audible alarm for 24 hours.

Indicator Lights

Alarm/Fault Condition

LED 1

(UV Controller 

Status)

LED 2

(UV Lamp 

Status)

Audio 

Indicator 

Status

Notes

UV Lamp Ignition/Run Fault

Red

Flashing 

Red

Beeping

1. 

Unplug UV system from main power supply.

2. 

Check for secure lamp connection.

3. 

Restore power to UV system.

4. 

If failure message repeats, replace UV lamp.

Audible alarm may be silenced for 24 Hours.

UV Lamp Near End of Life Warning

Green

Yellow

Off

Warning: Lamp will require replacement shortly.

UV Lamp At End of Life Fault

Green

Flashing 

Red

Chirp

1. 

Follow instructions in manual to replace lamp. 

Warning Chirp may be silenced for 7 Days.

UV Lamp EOL Exceeded Fault

Green

Flashing 

Red

Chirp

1. 

Follow instructions in manual to replace lamp. 

Warning Chirp may be silenced for 24 Hours.

AC Voltage out of Range

Flashing Red

Flashing 

Red

Beeping

When the AC voltage is back in range (>93V or <265V) the alarm 

cancels and normal operation is resumed.
Audible alarm may be silenced temporarily.

UV Controller Fault

Flashing Red

Red

Beeping

1. 

Unplug UV system from main power supply.

2. 

Allow 30 seconds for unit to fully power down.

3. 

Restore power to UV system. 

4. 

If failure message repeats, replace controller.

Audible alarm may be silenced for 24 Hours.

2

1

C

B

A

Summary of Contents for IHS10-D4

Page 1: ...o Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models IHS10 D4 IHS12 D4 IHS22 D4 Owner s Manua...

Page 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Page 3: ...ymbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electri...

Page 4: ...f the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey...

Page 5: ...6 Power cord 602636 120V IHS12 D4 IHS22 D4 IHS10 D4 602637 230V IHS12 D4 2 IHS22 D4 2 IHS10 D4 2 260013 Australian IHS12 D4 2A IHS22 D4 2A IHS10 D4 2A 260012 UK IHS12 D4 2B IHS22 D4 2B IHS10 D4 2B 7 C...

Page 6: ...hole Home System Provides filtration and disinfection of the water 6 Controller Powers and controls the UV lamp Provides human interface displaying information and allowing control inputs such as muti...

Page 7: ...in the metal bracket 2 Slide controller onto mounting bracket 3 Insert the reference card between controller and mounting bracket 4 Connect power cord to controller DO NOT connect the power cord to t...

Page 8: ...d any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemically disinfected to e...

Page 9: ...ure Inspect for any leaks Maintenance 9 Section 4 Maintenance Always disconnect power before performing any work on the disinfection system Always shut off water flow and release water pressure before...

Page 10: ...nd and turn lamp counter clockwise and pull the lamp outside the chamber in upward direction 5 1 2 Insert new lamp into the quartz sleeve and thread into sleeve bolt until hard stop 6 Connect the gree...

Page 11: ...ving sleeve bolt 2 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched...

Page 12: ...cool for 10 minutes 2 Shut off the water supply Close each faucet 3 Press the pressure button to release the pressure from the cartridges 4 Remove the drain plug at the bottom of the sump and place a...

Page 13: ...system from main power supply 2 Check for secure lamp connection 3 Restore power to UV system 4 If failure message repeats replace UV lamp Audible alarm may be silenced for 24 Hours UV Lamp Near End...

Page 14: ...assembly hand tight Alarm Refer to Section 5 1 Refer to Section 5 1 System is operating but water tests reveal bacterial contamination Equipment downstream of UV system is acting as a breeding ground...

Page 15: ...hr 16 gpm 60 lpm 3 6 m3 hr 16 gpm 60 lpm 3 6 m3 hr Maximum rated flow at dose of 30 mJ cm2 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr Maximum rated flow at dose of 40 mJ...

Page 16: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Page 17: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Reviews: