Maintenance
10
4.1 Replacing UV Lamp
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Procedure:
1
•
Close all faucets and water
supply.
•
Press the pressure button to
release the pressure from the
cartridges.
2
0
30
15
45
10 mins
•
Disconnect main power
source and allow the unit to
cool for 10 minutes.
3
1
2
•
Remove the lamp connector
by pulling the tabs out and
then upwards.
4
2
1
•
Hold sleeve bolt with one
hand and turn lamp counter-
clockwise and pull the lamp
outside the chamber in
upward direction.
5
1
2
•
Insert new lamp into the
quartz sleeve and thread into
sleeve bolt until hard stop.
6
•
Connect the green ground
wire and red strain relief wire
to the chamber using the
grounding screw.
7
•
Align connection pins with
the lamp connector by
rotating the ring clamp.
•
Push the lamp connector
down onto the lamp pins and
the ring clamp pins until an
audible click is heard.
Note:
Ensure the connector
is engaged on both sides.
8
•
Restore power.
•
If new lamp was inserted,
press and hold lamp timer
reset button for 5 seconds.
Display should read
.
•
Open all faucets and water
inlets, then close all faucets
and inspect for any leaks.
N O T I C E
Do not use water during replacement of UV lamp.