Maintenance

11

4.2 Cleaning and Replacing Quartz Sleeve

Note: 

Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces 

the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it 

must be replaced.

Prerequisites:

Shut off water supply and drain all lines.

Depressurize the unit. Place a small pail under the unit to catch any spills.

Remove the UV lamp. Refer to 

Section 4.1

.

Procedure:

1

2

1

•   

Unscrew the sleeve bolt and 
carefully remove it from the 
top of the chamber.

Note: 

Sleeve may be 

attached to sleeve bolt. Hold 
sleeve with other hand while 
removing sleeve bolt.

2

Mild 
Acid

•   

Clean the quartz sleeve with 
a cloth soaked in CLR, 
vinegar or some other mild 
acid and then rinse with 
water.

Note: 

If sleeve cannot be 

cleaned completely or it is 
scratched or cracked, then 
replace the sleeve.

3

•   

Place O-ring on the sleeve as 

shown. Insert the sleeve into 
the chamber as shown in 

step 4.

4

•   

Ensure quartz sleeve is 

properly centered in the 
chamber. 

5

2

1

•   

Place sleeve bolt onto the 
quartz sleeve, carefully push 
down and hand tighten onto 
chamber.

•   

When service is complete, 
assemble the prerequisites in 
the reverse order of 
disassembly.

Notes: 

1) After replacing the UV lamp or sleeve perform the disinfection procedure, refer to 

Section 3.2

.

2) If the system is put on a temporary by-pass or if it becomes contaminated after the disinfection system, it is 

necessary to complete the disinfection procedure. Refer to 

Section 3.2

Summary of Contents for IHS10-D4

Page 1: ...o Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models IHS10 D4 IHS12 D4 IHS22 D4 Owner s Manua...

Page 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Page 3: ...ymbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electri...

Page 4: ...f the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey...

Page 5: ...6 Power cord 602636 120V IHS12 D4 IHS22 D4 IHS10 D4 602637 230V IHS12 D4 2 IHS22 D4 2 IHS10 D4 2 260013 Australian IHS12 D4 2A IHS22 D4 2A IHS10 D4 2A 260012 UK IHS12 D4 2B IHS22 D4 2B IHS10 D4 2B 7 C...

Page 6: ...hole Home System Provides filtration and disinfection of the water 6 Controller Powers and controls the UV lamp Provides human interface displaying information and allowing control inputs such as muti...

Page 7: ...in the metal bracket 2 Slide controller onto mounting bracket 3 Insert the reference card between controller and mounting bracket 4 Connect power cord to controller DO NOT connect the power cord to t...

Page 8: ...d any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemically disinfected to e...

Page 9: ...ure Inspect for any leaks Maintenance 9 Section 4 Maintenance Always disconnect power before performing any work on the disinfection system Always shut off water flow and release water pressure before...

Page 10: ...nd and turn lamp counter clockwise and pull the lamp outside the chamber in upward direction 5 1 2 Insert new lamp into the quartz sleeve and thread into sleeve bolt until hard stop 6 Connect the gree...

Page 11: ...ving sleeve bolt 2 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched...

Page 12: ...cool for 10 minutes 2 Shut off the water supply Close each faucet 3 Press the pressure button to release the pressure from the cartridges 4 Remove the drain plug at the bottom of the sump and place a...

Page 13: ...system from main power supply 2 Check for secure lamp connection 3 Restore power to UV system 4 If failure message repeats replace UV lamp Audible alarm may be silenced for 24 Hours UV Lamp Near End...

Page 14: ...assembly hand tight Alarm Refer to Section 5 1 Refer to Section 5 1 System is operating but water tests reveal bacterial contamination Equipment downstream of UV system is acting as a breeding ground...

Page 15: ...hr 16 gpm 60 lpm 3 6 m3 hr 16 gpm 60 lpm 3 6 m3 hr Maximum rated flow at dose of 30 mJ cm2 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr Maximum rated flow at dose of 40 mJ...

Page 16: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Page 17: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Reviews: