© 2008 Directed Electronics- All rights reserved.
26
2-8 DOUBLE PULSE UNLOCK ON/OFF:
Some vehicles require two
pulses on a single wire to unlock the doors. When the double pulse unlock
feature is turned on, the BLUE H2/C wire will supply two negative pulses
instead of a single pulse. At the same time, the GREEN H2/A wire will supply
two positive pulses instead of a single pulse. This makes it possible to directly
interface with double pulse vehicles without any extra parts.
2-9 Double/Single Pulse Lock: Some vehicles require two pulses on a single
wire to lock the doors. When the double pulse lock feature is turned on, the
BLUE H2/C wire will supply two positive pulses instead of a single pulse. At
the same time the GREEN H2/A wire will supply two negative pulses instead
of a single pulse. This makes it possible to directly interface with double pulse
vehicles without any extra parts.
2-10 CHANNEL 3 VALIDITY/LATCHED/LATCHED RESET WITH
IGNITION/30 SECOND TIMED/SECOND UNLOCK OUTPUT:
Channel 3 can be programmed for these output configurations. The unit is set
to the default validity output. To change the configuration use the two-chirp
setting to toggle to the different configurations.
2-11 COMFORT CLOSURE: The system can be programmed to close the
windows when the system is armed. A 20-second output starts 200mS after the
last
�������
button pulse. The comfort closure output will be cancelled if the
�������
button is pressed. If programmed ON, the lock output wire will provide this
function.
NOTE: Comfort closure is deleted if one-time bypass is activated.