Transportation and storage
WARNING! 1. Local, national or international regulations may apply to the
transport and storage of pressurized pedestals.
2. The control valve
(26)
MUST be set to the WORK position
when degassing the pedestal, or only the pump volume will be
vented and the tank volume will remain.
3. Reducing the pedestal pressure below 3.5 bar (50 psi) will
cause the remaining pressure to leak.
NOTE:
It is not necessary to reduce the pedestal pressure prior to transportation or
storage. However, it is recommended to set the control valve
(26)
to PUMP, to
isolate the moving column
(5)
from the internal pressure.
Set the column to minimum height to avoid the possibility of dust or abrasive
particles collecting on moving components
.
Fig 5 Transportation and Storage
(20)
(19)