Fully collapse the moving column
(5)
and apply the safety catch
(24)
.
Set the control valve
(26)
to the TRANSITION position as follows:
Depress the control valve
(26)
against the spring force, rotate the lever to the vertical
position and allow the lever to extend under the spring force.
Set the control valve
(26)
to the WORK position as follows:
Ensure the moving column
(5)
is fully collapsed and the safety catch
(24)
is applied.
Depress the control valve
(26)
against the spring force, and rotate the lever fully
counter clockwise to a horizontal position, allowing the lever
(26)
to extend under the
spring force. The control valve
(26)
will remain in an extended position.
Pressurizing the pedestal using the Vinten portable pump
WARNING! Place the control valve
(26)
in the TRANSITION position for at
least 10-SECONDS when switching between PUMP and WORK
modes, to prevent the moving column
(5)
rising rapidly.
Fig 4 The Vinten Portable Pump
(P.1)
(P.5)
(P.2)
(P.4)
(P.3)