PATCH PROGRAMMING
Available programs are 100. 10 patch for 10 banks.
On any programs (patch) it is posssible to assign:
-
Any combination on/off of 10 loops
-
Any combination on/off of 4 swicth
-
buffer on/off
-
out A , out B
-
MUTE ( when MUTE is programmed no signal comes out from V-10 Clipper)
-
MIDI program change (1-128) and out channel (1-16)
-
Up to 5 Control Change (1-128) e related midi out channel OUT (1-16)
Programming Loops, switches, buffer, mute and A/B out
Whit white led “P” ON (selection with MD)
Hold button of choose program (from 1 to 10) . Keep it for about 3 seconds.
Blinkin of white led means that V-10 is in programming mode.
Press button of loops to be activated. Relative blue led will ON to show selection.
To select switches 1-4 keep pressed relative buttons (1, 2, 3, 4) for about 3 seconds up to red LED
switch light ON.
For BUFFER patch activation or deactivation press 7 and keep up to GREEN led come on or off .
For MUTE patch activation or deactivation press 7 and keep up to GREEN led come on or off .
OUT A and OUT B (relative to OUT L and OUT R in wiring) are always open (yellow led on)
To switches them OFF keep them pressed up to yellow leds comes OFF
Save and exit with MD
Chain up to 5 Control Change to one patch
While in programming of patch (WHITE LED LED BLINKING) press button UP.
Orange led will blink, to confirm assign procedure.
Pressing buttons 1 to 5 control change pre-assigned in GLOBAL (see GLOBAL 5), CC are chained
to patch program.
Display show CC 1 2 3 4 5 , followings preset done.
Save and exit with MD
To complete save procedure press once MD
PRESET NAME
While programmin (white led “P” blinking ) press DW
Procedure is similar to “sms text on phone”
Display show number of program (ex 001) followed by x……
Use the 1-10 buttons, following indication under button ( ex. 1= ABC1)
As soon as selected one letter display goes on following.
Max number of characters is 7 for any patch.
Save and exit with MD