GLOBAL FUNCTION 

 
GLOBAL allows predefinition of following operative parameters, as in following table. 
 

But 

ton 

FUNCTION 

COMMAND 

COMMAND  2 

VALUE 

OUT 
SAVE 

DEF

ULT 

MIDI in channel 

UP DW 

 

0 – omni 
1- 16 

MD 

MIDI out canne,  MASTER 

UP DW 

 

1-16 

MD 

MIDI numbering 0-127 / 1-128 

UP DW 

 

0 - 1 

MD 

External Tap Tempo  
Control Change  

UP DW 

 

0-127 

MD 

80 

 

Control Change assignament to 
buttons  1 2 3 4 5 

P1,P2,P3, P4, 
P5 
UP / DW 

P6-CC nr 

0-120 

MD 

000 

P7- OUT channel  1-16 

MD 

P8- CC value 

0-127 

MD 

000 

External expression pedal 
Expression pedal calibration   
Values assigament    

P1,P 2, P3 
UP, DW 

P1- pedale value 

0-255 

MD 

255-

255 

P2- LOW limit 

0-127 

MD 

000 

P3- HIGH limit 

0-127 

MD 

000 

Buffer ON / OFF global 

UP,  DW 

P10 

 

MD 

OFF 

 

 

 

 

 

 

Switch 1, 2, 3 e 4: latch, single 
shot, dual shot 

UP, DW 
1,2,3,4 

LATCH 
SINGLE SHOT 
DUAL SHOT 

 

MD 

LAT

CH 

10  BANKS activation 

UP, DW 

1-10 

ACTIVE 
OFF 

MD 

1-on 

 

 
GLOBAL FUNTION ENTER 

 
With blue led “L” press and hold MD for 4 seconds 
Display show GLOBAL 
Press button corresponding to wanted function 
 

1-

 

MIDI input channel 

Display show MIDI IN followed by a number from 00 to 16. 
00 is OMNI, all channels ON. 
Make selection with  UP and DW (down). 
Save and exit with  MD 
 

2-

 

MIDI output channe 

Display show MIDI OUT followed by a number from 1 to 16

 

Make selection with  UP and DW (down). 
Save and exit with  MD 

Nota: 

this selection is general, may be changed for any control change

  

  
 
 
 

 
 

Summary of Contents for V-10 CLIPPER

Page 1: ...manuele II 123 Tel 39 339 7626891 fax 39 011 547712 Laboratorio Via Limone 22 10141 Torino Nr Iscrizione RAEE IT08020000002500 web http www vinteck com e mail info vinteck com V 10 CLIPPER True bypass MIDI switching Pedalboard User manual Ed 01 rev 4 SW DCEA 0862 ...

Page 2: ...h serial and years of building It is very important to report this information in case of need of technical supply 2 general warnings o please read the operator manual before starting the use of V 8 and follow the informations o Maintenance must be operated ALWAYS with the instrument not connected to power supply Thank you very much for purchase of V 8 pedalboard We really hope that it will be goo...

Page 3: ...chine to check that the machine is supplied by an grounded single phase electrical cable and the plug has an effective earth terminal 3 instructions manual 3 1 This manual is addressed to following subjects Owner Operators Technical builder 3 2 Aiming of details in I M The manual contains a clear description of all technical specifications of the machine aimed at the transport adjusting maintenanc...

Page 4: ...d up to 5 control change with independent channel and value 12 banks 10 programs each total 120 programs Each bank may be activated or deactivated form 0 to 11 Direct acce on the fligh on loop with MODE function program loop MIDI TAP TEMPO with external pedals Control Change is assignable from 1 to 128 MIDI channel manager input output e 0 1 assignament MIDI external expression pedal managing with...

Page 5: ...nal to input of effetc R RETURN Segnal back from effect X LOOP fixed llops Usable for send return of alway active pedals in ex volume pedal See schematics IN Guitar or bass INPUT TUNER Tuner output Always on even in MUTE PEDALBOARD leds show 1 10 BLUE loop 1 to 10 S 1 4 RED switch on off 1 2 3 AND 4 MUTE orange MUTE on BFR GREEN buffer on OUT A e OUT B YELLOW outputs A LEFT and B RIGHT ON P WHITE ...

Page 6: ...pag 6 Edizione 01 revisione0 WIRING EXAMPLES Followings schematis are only examples Nor to be inted as LOW Personal choise in sound building is the only real referement Ex 1 8 effects in front 2 effects in send return Mono ...

Page 7: ...Vinteck V 10 CLIPPER pag 7 Edizione 01 revisione0 Ex 2 8 effects in front 2 stereo effects in Send return on 2 amps Line insulator on amp 2 Midi management and expressione MIDI pedal ...

Page 8: ...Vinteck V 10 CLIPPER pag 8 Edizione 01 revisione0 Ex 3 8 effects in front 2 couple of effects in stereo in fronte of 2 amps Line insulator on amp 2 Volume pedal after distorsion pedals ...

Page 9: ... function is activated Holding pressed MD with BLUE LED L on V10 goes in GLOBAL BUTTON UP and DW FUNCTIONS UP BUTTON With WHITE LED P ON increments the banks from 0 to 11 if banks are active Other functions In programming mode allows input in control change assign to patch With BLUE LED L ON holding pressed allows access to BANK ACTIVATION function DW BUTTON With WHITE LED P ON decrements the bank...

Page 10: ...ssigament P1 P 2 P3 UP DW P1 pedale value 0 255 MD 255 255 P2 LOW limit 0 127 MD 000 P3 HIGH limit 0 127 MD 000 7 Buffer ON OFF global UP DW P10 MD OFF 8 9 Switch 1 2 3 e 4 latch single shot dual shot UP DW 1 2 3 4 LATCH SINGLE SHOT DUAL SHOT MD LAT CH 10 BANKS activation UP DW 1 10 ACTIVE OFF MD 1 on GLOBAL FUNTION ENTER With blue led L press and hold MD for 4 seconds Display show GLOBAL Press bu...

Page 11: ... shows respectively CC1 000 CC2 000 CC3 000 CC4 000 CC5 000 For each single button is possible assign the CC the canne and the value Button 6 assign the nr of CC UP e DW for selection value from 1 to 120 Display show CC1 000 from 000 to 120 Button 7 asseign the CHANNEL of CC UP e DW for selection value from 1 to 16 Dispaly show CC CH 1 016 from 000 to 016 Button 8 assign the VALUE of CC UP e DW fo...

Page 12: ...t dual shot The 4 switches for amp channels may be preset in 3 operation ways o Latch o Single shot o Dual shot shot in ON second shot in OFF From GLOBAL press button 9 Display show SW1 LATCH With buttons 1 2 3 4 make selection swicth 1 2 3 4 With UP and DW select kind of LATCH SSHOT DSHOT Save and exit with MD 10 Bank activation V 10 CLIPPER may meorize up to 12 banks 10programs each For easy man...

Page 13: ... deactivation press 7 and keep up to GREEN led come on or off For MUTE patch activation or deactivation press 7 and keep up to GREEN led come on or off OUT A and OUT B relative to OUT L and OUT R in wiring are always open yellow led on To switches them OFF keep them pressed up to yellow leds comes OFF Save and exit with MD Chain up to 5 Control Change to one patch While in programming of patch WHI...

Page 14: ...fferent CHANNELS for any single program patch from 1 to 100 As default any program patch got corrisponding PROGRAM CHANGE 1 1 2 2 etc and send only 1 PC To set up PC anch channels Recall the program to modify 1 100 With white led P on press MD ank keep pressed for 3 seconds Display show 001 P1 001 001 patch P1 progarm 001 the number of CC With UP or DW it s possible to change the PC from 1 to 128 ...

Page 15: ...o times of power on and OFF Factory reset is not reversible 7 Spare parts Codice descrizione TB10S7 Button TB10BF Buffer integrated circuit V Series PS External power supply 8 warranty and terms V 10 CLIPPER is covered by warranty for 24 mounth from purchase Aany warranty will be made at the vinteck labs Lab via Limone 22 10141 Torino Italy Shipping cost are charged to customers after 1 year All o...

Page 16: ... and 93 68 EEC Standard s to which Conformity is Daclared EN 55103 1 EN 55103 2 and 60062 1998 Manufacturer Vinteck SAS di Guido Michetti C Corso Vittorio Emanuele II 123 10128 Torino ITALY The equipment identified here conforms to the Directive s and Standards specifed above Type of equipment Effects switching system Model TB10MKII TB5 V UNO V 8 V 5 V10 Data september 2007 Vinteck sas di Guido Mi...

Reviews: