Vinopro BU-22 Service Manual Download Page 11

 

19

 

 

  Control PCB Replace 

1. For BU-22     

Step 1: Unplug    the unit,    emove Control Box   

(Figure 5)

;

 

Step 2: Unplug Terminal   

(Figure 20)

 

Step 3 : Remove Control PCB and Replace it with new one.

 (Figure 20) 

 
2. For BU-58     (Figure 19) 

Step 1: Unplug    the unit, remove Control Box   

(Figure 11)

;

 

Step 2: Unplug Terminal   

(Figure 21) 

Step 3: Open the 4 Snaps of Control PCB by hand   

(Figure 21) 

Step 4 : Remove Control PCB and Replace it with new one.

 (Figure 21) 

Terminals

Screws (2pcs)

Control PCB

Bracket

Control PCB

Phillips

Screwdriver

Terminals

Control PCB

Bracket

Control PCB

Snaps

Control PCB

 

20

 

 

 Power PCB Replace  (Figure 22 & Figure 22-1)

 

Step 1:

 

Unplug    the unit, remove Control Box 

 

(

Figure 5 & Figure 11);

 

Step 2: Unplug Terminal     

Step 3: Hold the 4 Plastic Fasteners, and draw upward Power PCB carefully. 

 

Step 4: Replace Power PCB with new one.

 

 
1.For BU-22   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.For BU-58    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Plastic

Fastener

Power PCB

Terminals

Plastic

Fastener

Plastic

Fastener

Power PCB

Terminals

Summary of Contents for BU-22

Page 1: ...Machine 3 Gas Meter 4 Temp Meter CONTENTS Cooling System Fault Troubleshooting P1 How to re charge Refrigerant P2 Test After Repairing P2 Baffle Board and Control Box Disassembly P3 Solder Joints Pos...

Page 2: ...rge Refrigerant No YES Yes Check Rubber Foot Mounting Screw and Capillary Tube YES No Disassemble and Replace faulty part as below mentioned How to re charge Refrigerant R600a Step 1 Extract vacuum fr...

Page 3: ...Screw Screw Screw Screw A A B B D C D C AScrew C Screw B Screw Step 4 Pull Control Box out about 70mm away in Horizontal direction and unplug terminals of Power PCB carefully Take Control Box out Fig...

Page 4: ...ssure Solder Joint Evaporator Stopper Shelf Step 2 Unscrew the 5 screws No 1 5 on Separator Board Cover one by one Figure 8 Step 3 Pull Baffle Board out Caution Unplug Fan Connector carefully before p...

Page 5: ...as following figure and loose the 2 screws No 3 4 a little about 2mm away Figure 10 1 B A Screw at back of PCB Box D C Screw Phillips Screw Driver Step 5 Pull Control Box put Figure 10 2 Caution Unplu...

Page 6: ...ndenser Solder Joint I Suction Tube Low Pressure Tube Solder Joint J Discharge Tube High Pressure Tube Solder Joint K Connection Tube 3 Solder Joint 2 For BU 58 Figure 13 A Evaporator Solder Joint B C...

Page 7: ...appened caused by following reasons a Fan Shaft is broken b Fan running unstable due to part abased badly over time Solutions Replace faulty Fan as following steps Evaporator Cooling Fan replace Figur...

Page 8: ...Evaporator too far 1 Re Insert Capillary Tube into Evaporator with depth less than 15mm Re solder it and wrap it with Shock absorbing Clay 2 Re do vacuum extraction and re charge Refrigerant Page 2 2...

Page 9: ...ared Fig 18 2 Fan will be blocked even broken if Ice too much Ice too much inside Replace Fan with new one Fig 13 Fig 14 Temperature Unstable Problem Possible Cause Solutions Temperature Unstable Cool...

Page 10: ...es Figure 1 Figure 7 Step 2 Remove Baffle Board and Control Box Figure 5 Figure 9 Step3 Unplug all Terminal of Fan and Temp Senor Figure 5 Figure 9 Step 3 Unscrew Screws of Temp Senor Remove Temp Seno...

Page 11: ...ep 4 Remove Control PCB and Replace it with new one Figure 21 Terminals Screws 2pcs Control PCB Bracket Control PCB Phillips Screwdriver Terminals Control PCB Bracket Control PCB Snaps Control PCB Pow...

Page 12: ...minals For 7 Bottles Screws 2pcs Washer Hex Nut Transformer Terminals For 19 Bottles Screws 2pcs Washer Hex Nut Transformer Connector Position Control PCB Figure 24 Connector Position Power PCB Figure...

Page 13: ...k Absorbing Rubber Foot Bushing Hex Nut Spring Washer Flat Washer Compressor Bracket Clip Spring Terminal Cover Start Relay Overload Protector Compressor For 7 Bottles LED Light Replace Warning Unplug...

Reviews: