73
ACM Family - System Installation & Configuration
A100K10647
The recall function can also be activated via a two-step operation using
feature code 765:
Dial 765 + group number.
13.3.2
User interface
Using the recall function from an intercom station
1. Dial the
recall number
(e.g. 9084 or 765+84)
2. Press the
M-key
to record a message
3. Release the
M-key
to listen to the recording
4. Press
8
to dispatch the message or:
- Press the
M-key
to make a new recording
- Press
7
to repeat the message
- Press the
C-key
to cancel the message
Using the recall function from a telephone
1. Dial the
recall number
(e.g. 9084 or 765+84)
2. Press the
*-key
to record a message
3. Press the
#-key
to stop the recording and listen to the message
4. Press
8
to dispatch the message or:
- Press
*
to make a new recording
- Press
7
to repeat the message
-
Hang up
to cancel
13.3.3 Optional settings
The recall user interface and the recall attributes can be altered by
modifying parameter 2 (set in AlphaPro) of the recall directory number.
y e ault t is arameter as alue
RECALL OPTIONS
Value
parameter
2
Function
1
After playback to the group has finished, the group call and the initiator station will
proceed to normal Group Call mode, and can use the M-key to talk into the group
2
If the initiator station disconnects during playback to the group, the message is
terminated immediately
8
The initiator station will not listen to the playback to the group
32
The message is dispatched when pressing the C-key or hanging up (no need to
confirm by pressing 8)
128
There will be no gong before the group call
256
The group is a global group call
512
There is no need to use the M-key during the recording
arameter an e mo ifie to ange t e re all user inter a e an
different options can be combined.
Example:
I arameter
i e
t ere ill e no nee to ress t e
M-key to record and the message is dispatched when pressing the
C-key. This option can be useful when using the recall function from
telephones.
1. Dial the
recall number
(e.g. 9084)
2. Record message (no M-key)
3. Press the
C-key
or hang up to dispatch the message or:
- Press
7
(or
#
) to stop the recording and listen to the message
- Press the
M-key
(or
*
) to restart a recording